    Correction for Settlement of Parshall Flume

    Source: Journal of Irrigation and Drainage Engineering:;1993:;Volume ( 119 ):;issue: 006
    Author:
    A. Genovez
    ,
    S. Abt
    ,
    B. Florentin
    ,
    A. Garton
    DOI: 10.1061/(ASCE)0733-9437(1993)119:6(1081)
    Publisher: American Society of Civil Engineers
    Abstract: A study was conducted in the Hydraulics Laboratory of Colorado State University to evaluate how settlement affects the accuracy of 30.5‐ and 61.0‐cm (1‐ and 2‐ft) prefabricated metal Parshall flumes. The flumes were installed and tested for lateral, longitudinal, and combined lateral‐longitudinal slopes settlements. Flume slopes varied ±7%, and were conducted for free outfall conditions. The results indicated that the Parshall flume accuracy is slope‐dependent. The flume rating was in error approximately 28% for longitudinal slopes of ±5%, and approximately 10% for lateral settlement of ±5%. Flow rates used in this study ranged from 0.01 to 0.20 m
    • Download: (848.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Correction for Settlement of Parshall Flume

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/27502
    Collections
    • Journal of Irrigation and Drainage Engineering

    Show full item record

    contributor authorA. Genovez
    contributor authorS. Abt
    contributor authorB. Florentin
    contributor authorA. Garton
    date accessioned2017-05-08T20:47:54Z
    date available2017-05-08T20:47:54Z
    date copyrightNovember 1993
    date issued1993
    identifier other%28asce%290733-9437%281993%29119%3A6%281081%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/27502
    description abstractA study was conducted in the Hydraulics Laboratory of Colorado State University to evaluate how settlement affects the accuracy of 30.5‐ and 61.0‐cm (1‐ and 2‐ft) prefabricated metal Parshall flumes. The flumes were installed and tested for lateral, longitudinal, and combined lateral‐longitudinal slopes settlements. Flume slopes varied ±7%, and were conducted for free outfall conditions. The results indicated that the Parshall flume accuracy is slope‐dependent. The flume rating was in error approximately 28% for longitudinal slopes of ±5%, and approximately 10% for lateral settlement of ±5%. Flow rates used in this study ranged from 0.01 to 0.20 m
    publisherAmerican Society of Civil Engineers
    titleCorrection for Settlement of Parshall Flume
    typeJournal Paper
    journal volume119
    journal issue6
    journal titleJournal of Irrigation and Drainage Engineering
    identifier doi10.1061/(ASCE)0733-9437(1993)119:6(1081)
    treeJournal of Irrigation and Drainage Engineering:;1993:;Volume ( 119 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian