contributor authorA. Genovez
contributor authorS. Abt
contributor authorB. Florentin
contributor authorA. Garton
date accessioned2017-05-08T20:47:54Z
date available2017-05-08T20:47:54Z
date copyrightNovember 1993
date issued1993
identifier other%28asce%290733-9437%281993%29119%3A6%281081%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/27502
description abstractA study was conducted in the Hydraulics Laboratory of Colorado State University to evaluate how settlement affects the accuracy of 30.5‐ and 61.0‐cm (1‐ and 2‐ft) prefabricated metal Parshall flumes. The flumes were installed and tested for lateral, longitudinal, and combined lateral‐longitudinal slopes settlements. Flume slopes varied ±7%, and were conducted for free outfall conditions. The results indicated that the Parshall flume accuracy is slope‐dependent. The flume rating was in error approximately 28% for longitudinal slopes of ±5%, and approximately 10% for lateral settlement of ±5%. Flow rates used in this study ranged from 0.01 to 0.20 m
publisherAmerican Society of Civil Engineers
titleCorrection for Settlement of Parshall Flume
typeJournal Paper
journal volume119
journal issue6
journal titleJournal of Irrigation and Drainage Engineering
identifier doi10.1061/(ASCE)0733-9437(1993)119:6(1081)
treeJournal of Irrigation and Drainage Engineering:;1993:;Volume ( 119 ):;issue: 006