    The Matched Acoustic Generator

    Source: Journal of Dynamic Systems, Measurement, and Control:;1972:;volume( 094 ):;issue: 001::page 11
    Author:
    K. Toda
    ,
    G. Roffman
    ,
    A. I. Talkin
    DOI: 10.1115/1.3426527
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The design of a swept-frequency, acoustic generator for quickly measuring the insertion power gain and bandwidth of flueric components is described and illustrated. The generator is used to produce and measure the signal incident on flueric components without being affected by reflections from them. The components are connected to the generator by transmission lines. The output of the flueric component is measured in a line of the same diameter as the input line and long enough to attenuate reflections from the far end of the line to negligible levels. The generator produces a 17.7 × 10−3 kilopascal (2.6 × 10−3 psi) acoustic signal in a 1/8 in. (0.32 cm) line over the frequency range of 200 to 5000 Hz. The maximum error in the measurement of the incident pressure signal is approximately 5 percent. More precise construction of the generator could reduce the measurement error, but the accuracy is sufficient for many engineering purposes. The swept-frequency responses and carrier-pulse responses of several flueric amplifiers are illustrated and in particular the frequency response of certain proportional amplifiers has been shown to extend to 4000 Hz.
    keyword(s): Acoustics , Generators , Signals , Errors , Reflection , Construction , Design , Frequency response , Transmission lines AND Pressure ,
    • Download: (1.542Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Matched Acoustic Generator

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/160255
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorK. Toda
    contributor authorG. Roffman
    contributor authorA. I. Talkin
    date accessioned2017-05-09T01:25:42Z
    date available2017-05-09T01:25:42Z
    date copyrightMarch, 1972
    date issued1972
    identifier issn0022-0434
    identifier otherJDSMAA-25987#11_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160255
    description abstractThe design of a swept-frequency, acoustic generator for quickly measuring the insertion power gain and bandwidth of flueric components is described and illustrated. The generator is used to produce and measure the signal incident on flueric components without being affected by reflections from them. The components are connected to the generator by transmission lines. The output of the flueric component is measured in a line of the same diameter as the input line and long enough to attenuate reflections from the far end of the line to negligible levels. The generator produces a 17.7 × 10−3 kilopascal (2.6 × 10−3 psi) acoustic signal in a 1/8 in. (0.32 cm) line over the frequency range of 200 to 5000 Hz. The maximum error in the measurement of the incident pressure signal is approximately 5 percent. More precise construction of the generator could reduce the measurement error, but the accuracy is sufficient for many engineering purposes. The swept-frequency responses and carrier-pulse responses of several flueric amplifiers are illustrated and in particular the frequency response of certain proportional amplifiers has been shown to extend to 4000 Hz.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Matched Acoustic Generator
    typeJournal Paper
    journal volume94
    journal issue1
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.3426527
    journal fristpage11
    journal lastpage14
    identifier eissn1528-9028
    keywordsAcoustics
    keywordsGenerators
    keywordsSignals
    keywordsErrors
    keywordsReflection
    keywordsConstruction
    keywordsDesign
    keywordsFrequency response
    keywordsTransmission lines AND Pressure
    treeJournal of Dynamic Systems, Measurement, and Control:;1972:;volume( 094 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian