| contributor author | D. M. Auslander | |
| contributor author | T. E. Lobdell | |
| contributor author | D. Chong | |
| date accessioned | 2017-05-09T01:24:04Z | |
| date available | 2017-05-09T01:24:04Z | |
| date copyright | September, 1972 | |
| date issued | 1972 | |
| identifier issn | 0022-0434 | |
| identifier other | JDSMAA-25992#230_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/159800 | |
| description abstract | Bond graphs have been used to construct a distributed-parameter model of the human cardiovascular system. The model includes the heart and arterial, capillary, and venous segments of both the pulmonary and systemic circulations. Anatomical and physiological data were utilized in implementing the model on a large digital computer. Comparisons of simulated output and measured responses are shown. Because a general-purpose bond graph simulation language for distributed-parameter systems was used, this cardiovascular simulation retains considerable flexibility and can be modified to suit the application. One such application that has been investigated in detail is the simulation of the body motions caused by blood flow in a subject mechanically isolated from the earth. This measurement, the ballistocardiogram (BCG) holds the possibility of a noninvasive means of determining heart output. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Large-Scale Model of the Human Cardiovascular System and its Application to Ballistocardiography | |
| type | Journal Paper | |
| journal volume | 94 | |
| journal issue | 3 | |
| journal title | Journal of Dynamic Systems, Measurement, and Control | |
| identifier doi | 10.1115/1.3426593 | |
| journal fristpage | 230 | |
| journal lastpage | 238 | |
| identifier eissn | 1528-9028 | |
| keywords | Cardiovascular system | |
| keywords | Simulation | |
| keywords | Computers | |
| keywords | Plasticity | |
| keywords | Motion | |
| keywords | Physiology AND Blood flow | |
| tree | Journal of Dynamic Systems, Measurement, and Control:;1972:;volume( 094 ):;issue: 003 | |
| contenttype | Fulltext | |