Analytical and Experimental Investigation to Determine the Variation of Hottel–Whillier–Bliss Constants for a Scaled Forced Circulation Flat Plate Solar Water HeaterSource: Journal of Solar Energy Engineering:;2015:;volume( 137 ):;issue: 005::page 51011DOI: 10.1115/1.4031213Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Fixed tilt flatplate solar thermal collectors, popularly known as solar water heaters, still remain as one of the most interesting technologies for utilization of solar energy. The system performance deteriorates due to scaling because of the continuous use of hard water as feed water. The present study deals with the experimental and analytical approach to determine the variation of Hottel–Whillier–Bliss (H–W–B) constants (which compactly represent the efficiency characteristics of a solar water heater) due to variation in solar power input and degree of scaling in case of forced circulation system (FCS) without considering the variation of input power to the circulating pump. Indoor tests are performed with a copper tube to investigate the flow characteristics. This forms a part of conventional FCS, in place of the usual ninefin tube array in a fullfledged collector. In indoor tests, electrical heating is favored to simulate solar radiation level. Various energy parameters are determined and compared by incorporating the developed numerical code FLATSCALE. Variation between experimental and analytical mass flow rate, overall heat loss coefficient, and H–W–B constants with simulated solar radiation level is plotted. In scaled condition, the drop in instantaneous efficiency is due to both scale thickness and reduced water flow rate. Scale thickness acts as an additional thermal conductive resistance between absorber plate and flowing water. Overall heat loss coefficient increases as absorber plate temperature is high during reduced flow rate. The maximum deviation observed is 21.68% in mass flow rate, 14.64% in absorber plate mean temperature, 7.86% in overall heat loss coefficient, and 12.04% in instantaneous efficiency. Compared to a clean tube, a highly scaled tube of 3.7 mm scale thickness indicates a drop of 4.76% in instantaneous efficiency and 40.28% in mass flow rate. It is concluded that the growth of scale in FCS does not affect the instantaneous efficiency significantly because of the margin in heat carrying capacity of water in spite of high drop in the flow rate.
|
Collections
Show full item record
| contributor author | Arunachala, U. C. | |
| contributor author | Siddhartha Bhatt, M. | |
| contributor author | Sreepathi, L. K. | |
| date accessioned | 2017-05-09T01:23:36Z | |
| date available | 2017-05-09T01:23:36Z | |
| date issued | 2015 | |
| identifier issn | 0199-6231 | |
| identifier other | sol_137_05_051011.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/159655 | |
| description abstract | Fixed tilt flatplate solar thermal collectors, popularly known as solar water heaters, still remain as one of the most interesting technologies for utilization of solar energy. The system performance deteriorates due to scaling because of the continuous use of hard water as feed water. The present study deals with the experimental and analytical approach to determine the variation of Hottel–Whillier–Bliss (H–W–B) constants (which compactly represent the efficiency characteristics of a solar water heater) due to variation in solar power input and degree of scaling in case of forced circulation system (FCS) without considering the variation of input power to the circulating pump. Indoor tests are performed with a copper tube to investigate the flow characteristics. This forms a part of conventional FCS, in place of the usual ninefin tube array in a fullfledged collector. In indoor tests, electrical heating is favored to simulate solar radiation level. Various energy parameters are determined and compared by incorporating the developed numerical code FLATSCALE. Variation between experimental and analytical mass flow rate, overall heat loss coefficient, and H–W–B constants with simulated solar radiation level is plotted. In scaled condition, the drop in instantaneous efficiency is due to both scale thickness and reduced water flow rate. Scale thickness acts as an additional thermal conductive resistance between absorber plate and flowing water. Overall heat loss coefficient increases as absorber plate temperature is high during reduced flow rate. The maximum deviation observed is 21.68% in mass flow rate, 14.64% in absorber plate mean temperature, 7.86% in overall heat loss coefficient, and 12.04% in instantaneous efficiency. Compared to a clean tube, a highly scaled tube of 3.7 mm scale thickness indicates a drop of 4.76% in instantaneous efficiency and 40.28% in mass flow rate. It is concluded that the growth of scale in FCS does not affect the instantaneous efficiency significantly because of the margin in heat carrying capacity of water in spite of high drop in the flow rate. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Analytical and Experimental Investigation to Determine the Variation of Hottel–Whillier–Bliss Constants for a Scaled Forced Circulation Flat Plate Solar Water Heater | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 5 | |
| journal title | Journal of Solar Energy Engineering | |
| identifier doi | 10.1115/1.4031213 | |
| journal fristpage | 51011 | |
| journal lastpage | 51011 | |
| identifier eissn | 1528-8986 | |
| tree | Journal of Solar Energy Engineering:;2015:;volume( 137 ):;issue: 005 | |
| contenttype | Fulltext |