Show simple item record

contributor authorArunachala, U. C.
contributor authorSiddhartha Bhatt, M.
contributor authorSreepathi, L. K.
date accessioned2017-05-09T01:23:36Z
date available2017-05-09T01:23:36Z
date issued2015
identifier issn0199-6231
identifier othersol_137_05_051011.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159655
description abstractFixed tilt flatplate solar thermal collectors, popularly known as solar water heaters, still remain as one of the most interesting technologies for utilization of solar energy. The system performance deteriorates due to scaling because of the continuous use of hard water as feed water. The present study deals with the experimental and analytical approach to determine the variation of Hottel–Whillier–Bliss (H–W–B) constants (which compactly represent the efficiency characteristics of a solar water heater) due to variation in solar power input and degree of scaling in case of forced circulation system (FCS) without considering the variation of input power to the circulating pump. Indoor tests are performed with a copper tube to investigate the flow characteristics. This forms a part of conventional FCS, in place of the usual ninefin tube array in a fullfledged collector. In indoor tests, electrical heating is favored to simulate solar radiation level. Various energy parameters are determined and compared by incorporating the developed numerical code FLATSCALE. Variation between experimental and analytical mass flow rate, overall heat loss coefficient, and H–W–B constants with simulated solar radiation level is plotted. In scaled condition, the drop in instantaneous efficiency is due to both scale thickness and reduced water flow rate. Scale thickness acts as an additional thermal conductive resistance between absorber plate and flowing water. Overall heat loss coefficient increases as absorber plate temperature is high during reduced flow rate. The maximum deviation observed is 21.68% in mass flow rate, 14.64% in absorber plate mean temperature, 7.86% in overall heat loss coefficient, and 12.04% in instantaneous efficiency. Compared to a clean tube, a highly scaled tube of 3.7 mm scale thickness indicates a drop of 4.76% in instantaneous efficiency and 40.28% in mass flow rate. It is concluded that the growth of scale in FCS does not affect the instantaneous efficiency significantly because of the margin in heat carrying capacity of water in spite of high drop in the flow rate.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalytical and Experimental Investigation to Determine the Variation of Hottel–Whillier–Bliss Constants for a Scaled Forced Circulation Flat Plate Solar Water Heater
typeJournal Paper
journal volume137
journal issue5
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4031213
journal fristpage51011
journal lastpage51011
identifier eissn1528-8986
treeJournal of Solar Energy Engineering:;2015:;volume( 137 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record