    Development of a New Calibration Procedure and Its Experimental Validation Applied to a Human Motion Capture System

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 012::page 124502
    Author:
    Royo Sأ،nchez, Ana Cristina
    ,
    Aguilar Martأ­n, Juan Josأ©
    ,
    Santolaria Mazo, Jorge
    DOI: 10.1115/1.4028523
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Motion capture systems are often used for checking and analyzing human motion in biomechanical applications. It is important, in this context, that the systems provide the best possible accuracy. Among existing capture systems, optical systems are those with the highest accuracy. In this paper, the development of a new calibration procedure for optical human motion capture systems is presented. The performance and effectiveness of that new calibration procedure are also checked by experimental validation. The new calibration procedure consists of two stages. In the first stage, initial estimators of intrinsic and extrinsic parameters are sought. The camera calibration method used in this stage is the one proposed by Tsai. These parameters are determined from the camera characteristics, the spatial position of the camera, and the center of the capture volume. In the second stage, a simultaneous nonlinear optimization of all parameters is performed to identify the optimal values, which minimize the objective function. The objective function, in this case, minimizes two errors. The first error is the distance error between two markers placed in a wand. The second error is the error of position and orientation of the retroreflective markers of a static calibration object. The real coordinates of the two objects are calibrated in a coordinate measuring machine (CMM). The OrthoBio system is used to validate the new calibration procedure. Results are 90% lower than those from the previous calibration software and broadly comparable with results from a similarly configured Vicon system.
    • Download: (950.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development of a New Calibration Procedure and Its Experimental Validation Applied to a Human Motion Capture System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/154118
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorRoyo Sأ،nchez, Ana Cristina
    contributor authorAguilar Martأ­n, Juan Josأ©
    contributor authorSantolaria Mazo, Jorge
    date accessioned2017-05-09T01:05:45Z
    date available2017-05-09T01:05:45Z
    date issued2014
    identifier issn0148-0731
    identifier otherbio_136_12_124502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154118
    description abstractMotion capture systems are often used for checking and analyzing human motion in biomechanical applications. It is important, in this context, that the systems provide the best possible accuracy. Among existing capture systems, optical systems are those with the highest accuracy. In this paper, the development of a new calibration procedure for optical human motion capture systems is presented. The performance and effectiveness of that new calibration procedure are also checked by experimental validation. The new calibration procedure consists of two stages. In the first stage, initial estimators of intrinsic and extrinsic parameters are sought. The camera calibration method used in this stage is the one proposed by Tsai. These parameters are determined from the camera characteristics, the spatial position of the camera, and the center of the capture volume. In the second stage, a simultaneous nonlinear optimization of all parameters is performed to identify the optimal values, which minimize the objective function. The objective function, in this case, minimizes two errors. The first error is the distance error between two markers placed in a wand. The second error is the error of position and orientation of the retroreflective markers of a static calibration object. The real coordinates of the two objects are calibrated in a coordinate measuring machine (CMM). The OrthoBio system is used to validate the new calibration procedure. Results are 90% lower than those from the previous calibration software and broadly comparable with results from a similarly configured Vicon system.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of a New Calibration Procedure and Its Experimental Validation Applied to a Human Motion Capture System
    typeJournal Paper
    journal volume136
    journal issue12
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4028523
    journal fristpage124502
    journal lastpage124502
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian