Show simple item record

contributor authorRoyo Sأ،nchez, Ana Cristina
contributor authorAguilar Martأ­n, Juan Josأ©
contributor authorSantolaria Mazo, Jorge
date accessioned2017-05-09T01:05:45Z
date available2017-05-09T01:05:45Z
date issued2014
identifier issn0148-0731
identifier otherbio_136_12_124502.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154118
description abstractMotion capture systems are often used for checking and analyzing human motion in biomechanical applications. It is important, in this context, that the systems provide the best possible accuracy. Among existing capture systems, optical systems are those with the highest accuracy. In this paper, the development of a new calibration procedure for optical human motion capture systems is presented. The performance and effectiveness of that new calibration procedure are also checked by experimental validation. The new calibration procedure consists of two stages. In the first stage, initial estimators of intrinsic and extrinsic parameters are sought. The camera calibration method used in this stage is the one proposed by Tsai. These parameters are determined from the camera characteristics, the spatial position of the camera, and the center of the capture volume. In the second stage, a simultaneous nonlinear optimization of all parameters is performed to identify the optimal values, which minimize the objective function. The objective function, in this case, minimizes two errors. The first error is the distance error between two markers placed in a wand. The second error is the error of position and orientation of the retroreflective markers of a static calibration object. The real coordinates of the two objects are calibrated in a coordinate measuring machine (CMM). The OrthoBio system is used to validate the new calibration procedure. Results are 90% lower than those from the previous calibration software and broadly comparable with results from a similarly configured Vicon system.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment of a New Calibration Procedure and Its Experimental Validation Applied to a Human Motion Capture System
typeJournal Paper
journal volume136
journal issue12
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4028523
journal fristpage124502
journal lastpage124502
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record