Comparison of Strain-Gage and Fiber-Optic Goniometry for Measuring Knee Kinematics During Activities of Daily Living and ExerciseSource: Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 008::page 84502Author:Abeer A. Mohamed
,
James Beyea
,
John Landry
,
Chris A. McGibbon
,
Andrew Sexton
,
Jennifer Baba
DOI: 10.1115/1.4007094Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: There is increasing interest in wearable sensor technology as a tool for rehabilitation applications in community or home environments. Recent studies have focused on evaluating inertial based sensing (accelerometers, gyroscopes, etc.) that provide only indirect measures of joint motion. Measurement of joint kinematics using flexible goniometry is more direct, and still popular in laboratory environments, but has received little attention as a potential tool for wearable systems. The aim of this study was to compare two goniometric devices: a traditional strain-gauge flexible goniometer, and a fiberoptic flexible goniometer, for measuring dynamic knee flexion/extension angles during activity of daily living: chair rise, and gait; and exercise: deep knee bends, against joint angles computed from a “gold standard” Vicon motion tracking system. Six young adults were recruited to perform the above activities in the lab while wearing a goniometer on each knee, and reflective markers for motion tracking. Kinematic data were collected simultaneously from the goniometers (one on each leg) and the motion tracking system (both legs). The results indicate that both goniometers were within 2–5 degrees of the Vicon angles for gait and chair rise. For some deep knee bend trials, disagreement with Vicon angles exceeded ten degrees for both devices. We conclude that both goniometers can record ADL knee movement faithfully and accurately, but should be carefully considered when high (>120 deg) knee flexion angles are required.
keyword(s): Knee , Motion , Strain gages , Kinematics AND Sensors ,
|
Collections
Show full item record
| contributor author | Abeer A. Mohamed | |
| contributor author | James Beyea | |
| contributor author | John Landry | |
| contributor author | Chris A. McGibbon | |
| contributor author | Andrew Sexton | |
| contributor author | Jennifer Baba | |
| date accessioned | 2017-05-09T00:48:26Z | |
| date available | 2017-05-09T00:48:26Z | |
| date copyright | August, 2012 | |
| date issued | 2012 | |
| identifier issn | 0148-0731 | |
| identifier other | JBENDY-29000#084502_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/148226 | |
| description abstract | There is increasing interest in wearable sensor technology as a tool for rehabilitation applications in community or home environments. Recent studies have focused on evaluating inertial based sensing (accelerometers, gyroscopes, etc.) that provide only indirect measures of joint motion. Measurement of joint kinematics using flexible goniometry is more direct, and still popular in laboratory environments, but has received little attention as a potential tool for wearable systems. The aim of this study was to compare two goniometric devices: a traditional strain-gauge flexible goniometer, and a fiberoptic flexible goniometer, for measuring dynamic knee flexion/extension angles during activity of daily living: chair rise, and gait; and exercise: deep knee bends, against joint angles computed from a “gold standard” Vicon motion tracking system. Six young adults were recruited to perform the above activities in the lab while wearing a goniometer on each knee, and reflective markers for motion tracking. Kinematic data were collected simultaneously from the goniometers (one on each leg) and the motion tracking system (both legs). The results indicate that both goniometers were within 2–5 degrees of the Vicon angles for gait and chair rise. For some deep knee bend trials, disagreement with Vicon angles exceeded ten degrees for both devices. We conclude that both goniometers can record ADL knee movement faithfully and accurately, but should be carefully considered when high (>120 deg) knee flexion angles are required. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Comparison of Strain-Gage and Fiber-Optic Goniometry for Measuring Knee Kinematics During Activities of Daily Living and Exercise | |
| type | Journal Paper | |
| journal volume | 134 | |
| journal issue | 8 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4007094 | |
| journal fristpage | 84502 | |
| identifier eissn | 1528-8951 | |
| keywords | Knee | |
| keywords | Motion | |
| keywords | Strain gages | |
| keywords | Kinematics AND Sensors | |
| tree | Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 008 | |
| contenttype | Fulltext |