    Modeling Embryo Transfer into a Closed Uterine Cavity

    Source: Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 011::page 111003
    Author:
    Sarit Yaniv
    ,
    Ariel J. Jaffa
    ,
    David Elad
    DOI: 10.1115/1.4007628
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Embryo transfer (ET) is the last manual intervention after extracorporeal fertilization. After the ET procedure is completed, the embryos are conveyed in the uterus for another two to four days due to spontaneous uterine peristalsis until the window time for implantation. The role of intrauterine fluid flow patterns in transporting the embryos to their implantation site during and after ET was simulated by injection of a liquid bolus into a two-dimensional liquid-filled channel with a closed fundal end via a liquid-filled catheter inserted in the channel. Numerical experiments revealed that the intrauterine fluid field and the embryos transport pattern were strongly affected by the closed fundal end. The embryos re-circulated in small loops around the vicinity where they were deposited from the catheter. The transport pattern was controlled by the uterine peristalsis factors, such as amplitude and frequency of the uterine walls motility, as well as the synchronization between the onset of catheter discharge and uterine peristalsis. The outcome of ET was also dependent on operating parameters such as placement of the catheter tip within the uterine cavity and the delivery speed of the catheter load. In conclusion, this modeling study highlighted important parameters that should be considered during ET procedures in order to increase the potential for pregnancy success.
    keyword(s): Fluids , Channels (Hydraulic engineering) , Stress , Modeling , Catheters , Cavities , Particulate matter , Performance AND Synchronization ,
    • Download: (1.233Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Modeling Embryo Transfer into a Closed Uterine Cavity

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/148183
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSarit Yaniv
    contributor authorAriel J. Jaffa
    contributor authorDavid Elad
    date accessioned2017-05-09T00:48:19Z
    date available2017-05-09T00:48:19Z
    date copyrightNovember, 2012
    date issued2012
    identifier issn0148-0731
    identifier otherJBENDY-926471#111003_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148183
    description abstractEmbryo transfer (ET) is the last manual intervention after extracorporeal fertilization. After the ET procedure is completed, the embryos are conveyed in the uterus for another two to four days due to spontaneous uterine peristalsis until the window time for implantation. The role of intrauterine fluid flow patterns in transporting the embryos to their implantation site during and after ET was simulated by injection of a liquid bolus into a two-dimensional liquid-filled channel with a closed fundal end via a liquid-filled catheter inserted in the channel. Numerical experiments revealed that the intrauterine fluid field and the embryos transport pattern were strongly affected by the closed fundal end. The embryos re-circulated in small loops around the vicinity where they were deposited from the catheter. The transport pattern was controlled by the uterine peristalsis factors, such as amplitude and frequency of the uterine walls motility, as well as the synchronization between the onset of catheter discharge and uterine peristalsis. The outcome of ET was also dependent on operating parameters such as placement of the catheter tip within the uterine cavity and the delivery speed of the catheter load. In conclusion, this modeling study highlighted important parameters that should be considered during ET procedures in order to increase the potential for pregnancy success.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleModeling Embryo Transfer into a Closed Uterine Cavity
    typeJournal Paper
    journal volume134
    journal issue11
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4007628
    journal fristpage111003
    identifier eissn1528-8951
    keywordsFluids
    keywordsChannels (Hydraulic engineering)
    keywordsStress
    keywordsModeling
    keywordsCatheters
    keywordsCavities
    keywordsParticulate matter
    keywordsPerformance AND Synchronization
    treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian