    A Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements

    Source: Journal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 007::page 74503
    Author:
    Habiba Bougherara
    ,
    Rad Zdero
    ,
    Ehsan Rahim
    ,
    Suraj Shah
    ,
    Anton Dubov
    ,
    Emil H. Schemitsch
    DOI: 10.1115/1.4004414
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: With the resurgence of composite materials in orthopaedic applications, a rigorous assessment of stress is needed to predict any failure of bone-implant systems. For current biomechanics research, strain gage measurements are employed to experimentally validate finite element models, which then characterize stress in the bone and implant. Our preliminary study experimentally validates a relatively new nondestructive testing technique for orthopaedic implants. Lock-in infrared (IR) thermography validated with strain gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N with the implant at an adduction angle of 15 deg to simulate the single-legged stance phase of walking gait. Three-dimensional surface stress maps were also obtained using an IR thermography camera. Results showed almost perfect agreement of IR thermography versus strain gage data with a Pearson correlation of R2 = 0.96 and a slope = 1.01 for the line of best fit. IR thermography detected hip implant peak stresses on the inferior-medial side just distal to the neck region of 31.14 MPa (at 840 N), 72.16 MPa (at 1500 N), and 119.86 MPa (at 2100 N). There was strong correlation between IR thermography-measured stresses and force application level at key locations on the implant along the medial (R2 = 0.99) and lateral (R2 = 0.83 to 0.99) surface, as well as at the peak stress point (R2 = 0.81 to 0.97). This is the first study to experimentally validate and demonstrate the use of lock-in IR thermography to obtain three-dimensional stress fields of an orthopaedic device manufactured from a composite material.
    keyword(s): Thermography , Stress , Biomechanics , Strain gages , Hip joint prostheses , Force , Composite materials AND Measurement ,
    • Download: (695.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/145424
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorHabiba Bougherara
    contributor authorRad Zdero
    contributor authorEhsan Rahim
    contributor authorSuraj Shah
    contributor authorAnton Dubov
    contributor authorEmil H. Schemitsch
    date accessioned2017-05-09T00:42:27Z
    date available2017-05-09T00:42:27Z
    date copyrightJuly, 2011
    date issued2011
    identifier issn0148-0731
    identifier otherJBENDY-27212#074503_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145424
    description abstractWith the resurgence of composite materials in orthopaedic applications, a rigorous assessment of stress is needed to predict any failure of bone-implant systems. For current biomechanics research, strain gage measurements are employed to experimentally validate finite element models, which then characterize stress in the bone and implant. Our preliminary study experimentally validates a relatively new nondestructive testing technique for orthopaedic implants. Lock-in infrared (IR) thermography validated with strain gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N with the implant at an adduction angle of 15 deg to simulate the single-legged stance phase of walking gait. Three-dimensional surface stress maps were also obtained using an IR thermography camera. Results showed almost perfect agreement of IR thermography versus strain gage data with a Pearson correlation of R2 = 0.96 and a slope = 1.01 for the line of best fit. IR thermography detected hip implant peak stresses on the inferior-medial side just distal to the neck region of 31.14 MPa (at 840 N), 72.16 MPa (at 1500 N), and 119.86 MPa (at 2100 N). There was strong correlation between IR thermography-measured stresses and force application level at key locations on the implant along the medial (R2 = 0.99) and lateral (R2 = 0.83 to 0.99) surface, as well as at the peak stress point (R2 = 0.81 to 0.97). This is the first study to experimentally validate and demonstrate the use of lock-in IR thermography to obtain three-dimensional stress fields of an orthopaedic device manufactured from a composite material.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements
    typeJournal Paper
    journal volume133
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4004414
    journal fristpage74503
    identifier eissn1528-8951
    keywordsThermography
    keywordsStress
    keywordsBiomechanics
    keywordsStrain gages
    keywordsHip joint prostheses
    keywordsForce
    keywordsComposite materials AND Measurement
    treeJournal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian