Show simple item record

contributor authorHabiba Bougherara
contributor authorRad Zdero
contributor authorEhsan Rahim
contributor authorSuraj Shah
contributor authorAnton Dubov
contributor authorEmil H. Schemitsch
date accessioned2017-05-09T00:42:27Z
date available2017-05-09T00:42:27Z
date copyrightJuly, 2011
date issued2011
identifier issn0148-0731
identifier otherJBENDY-27212#074503_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145424
description abstractWith the resurgence of composite materials in orthopaedic applications, a rigorous assessment of stress is needed to predict any failure of bone-implant systems. For current biomechanics research, strain gage measurements are employed to experimentally validate finite element models, which then characterize stress in the bone and implant. Our preliminary study experimentally validates a relatively new nondestructive testing technique for orthopaedic implants. Lock-in infrared (IR) thermography validated with strain gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N with the implant at an adduction angle of 15 deg to simulate the single-legged stance phase of walking gait. Three-dimensional surface stress maps were also obtained using an IR thermography camera. Results showed almost perfect agreement of IR thermography versus strain gage data with a Pearson correlation of R2 = 0.96 and a slope = 1.01 for the line of best fit. IR thermography detected hip implant peak stresses on the inferior-medial side just distal to the neck region of 31.14 MPa (at 840 N), 72.16 MPa (at 1500 N), and 119.86 MPa (at 2100 N). There was strong correlation between IR thermography-measured stresses and force application level at key locations on the implant along the medial (R2 = 0.99) and lateral (R2 = 0.83 to 0.99) surface, as well as at the peak stress point (R2 = 0.81 to 0.97). This is the first study to experimentally validate and demonstrate the use of lock-in IR thermography to obtain three-dimensional stress fields of an orthopaedic device manufactured from a composite material.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements
typeJournal Paper
journal volume133
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4004414
journal fristpage74503
identifier eissn1528-8951
keywordsThermography
keywordsStress
keywordsBiomechanics
keywordsStrain gages
keywordsHip joint prostheses
keywordsForce
keywordsComposite materials AND Measurement
treeJournal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record