    Patterns of Airflow in Circular Tubes Caused by a Corona Jet With Concentric and Eccentric Wire Electrodes

    Source: Journal of Fluids Engineering:;2010:;volume( 132 ):;issue: 008::page 81201
    Author:
    Reza Baghaei Lakeh
    ,
    Majid Molki
    DOI: 10.1115/1.4002008
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A computational investigation is conducted to study the patterns of airflow induced by corona discharge in the cross section of a circular tube. The secondary flow induced by corona wind in various flow passages has been the subject of numerous investigations. The flow patterns are often identified by multiple recirculation bubbles. Such flow patterns have also been anticipated for circular cross sections where the corona discharge is activated by an electrode situated at the center of the cross section. In this investigation, it is shown that, contrary to public perception, a symmetric corona discharge does not generate a secondary flow in circular cross sections. This investigation then proceeds to demonstrate that the flow responsible for thermal enhancements in circular tubes often reported in the published literature is induced only when there is a slight asymmetry in the position of the electrode. The present computations are performed in two parts. In part one, the electric field equations are solved using the method of characteristics. In part two, the flow equations are solved using a finite-volume method. It is shown that the method of characteristics effectively eliminates the dispersion errors observed in other numerical solutions. The present computations show that the flow in the eccentric configuration is characterized by a corona jet that is oriented along the eccentricity direction and two recirculation zones situated on either sides of the jet. In addition to the computational approach, a number of analytical solutions are presented and compared with the computational results.
    keyword(s): Flow (Dynamics) , Electric fields , Electrodes , Computation , Equations , Force , Air flow , Wire AND Electrohydrodynamics ,
    • Download: (777.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Patterns of Airflow in Circular Tubes Caused by a Corona Jet With Concentric and Eccentric Wire Electrodes

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/143437
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorReza Baghaei Lakeh
    contributor authorMajid Molki
    date accessioned2017-05-09T00:38:10Z
    date available2017-05-09T00:38:10Z
    date copyrightAugust, 2010
    date issued2010
    identifier issn0098-2202
    identifier otherJFEGA4-27426#081201_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/143437
    description abstractA computational investigation is conducted to study the patterns of airflow induced by corona discharge in the cross section of a circular tube. The secondary flow induced by corona wind in various flow passages has been the subject of numerous investigations. The flow patterns are often identified by multiple recirculation bubbles. Such flow patterns have also been anticipated for circular cross sections where the corona discharge is activated by an electrode situated at the center of the cross section. In this investigation, it is shown that, contrary to public perception, a symmetric corona discharge does not generate a secondary flow in circular cross sections. This investigation then proceeds to demonstrate that the flow responsible for thermal enhancements in circular tubes often reported in the published literature is induced only when there is a slight asymmetry in the position of the electrode. The present computations are performed in two parts. In part one, the electric field equations are solved using the method of characteristics. In part two, the flow equations are solved using a finite-volume method. It is shown that the method of characteristics effectively eliminates the dispersion errors observed in other numerical solutions. The present computations show that the flow in the eccentric configuration is characterized by a corona jet that is oriented along the eccentricity direction and two recirculation zones situated on either sides of the jet. In addition to the computational approach, a number of analytical solutions are presented and compared with the computational results.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePatterns of Airflow in Circular Tubes Caused by a Corona Jet With Concentric and Eccentric Wire Electrodes
    typeJournal Paper
    journal volume132
    journal issue8
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4002008
    journal fristpage81201
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsElectric fields
    keywordsElectrodes
    keywordsComputation
    keywordsEquations
    keywordsForce
    keywordsAir flow
    keywordsWire AND Electrohydrodynamics
    treeJournal of Fluids Engineering:;2010:;volume( 132 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian