contributor authorReza Baghaei Lakeh
contributor authorMajid Molki
date accessioned2017-05-09T00:38:10Z
date available2017-05-09T00:38:10Z
date copyrightAugust, 2010
date issued2010
identifier issn0098-2202
identifier otherJFEGA4-27426#081201_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/143437
description abstractA computational investigation is conducted to study the patterns of airflow induced by corona discharge in the cross section of a circular tube. The secondary flow induced by corona wind in various flow passages has been the subject of numerous investigations. The flow patterns are often identified by multiple recirculation bubbles. Such flow patterns have also been anticipated for circular cross sections where the corona discharge is activated by an electrode situated at the center of the cross section. In this investigation, it is shown that, contrary to public perception, a symmetric corona discharge does not generate a secondary flow in circular cross sections. This investigation then proceeds to demonstrate that the flow responsible for thermal enhancements in circular tubes often reported in the published literature is induced only when there is a slight asymmetry in the position of the electrode. The present computations are performed in two parts. In part one, the electric field equations are solved using the method of characteristics. In part two, the flow equations are solved using a finite-volume method. It is shown that the method of characteristics effectively eliminates the dispersion errors observed in other numerical solutions. The present computations show that the flow in the eccentric configuration is characterized by a corona jet that is oriented along the eccentricity direction and two recirculation zones situated on either sides of the jet. In addition to the computational approach, a number of analytical solutions are presented and compared with the computational results.
publisherThe American Society of Mechanical Engineers (ASME)
titlePatterns of Airflow in Circular Tubes Caused by a Corona Jet With Concentric and Eccentric Wire Electrodes
typeJournal Paper
journal volume132
journal issue8
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.4002008
journal fristpage81201
identifier eissn1528-901X
keywordsFlow (Dynamics)
keywordsElectric fields
keywordsElectrodes
keywordsComputation
keywordsEquations
keywordsForce
keywordsAir flow
keywordsWire AND Electrohydrodynamics