    Gait Modification via Verbal Instruction and an Active Feedback System to Reduce Peak Knee Adduction Moment

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 007::page 71007
    Author:
    Ariel V. Dowling
    ,
    David S. Fisher
    ,
    Thomas P. Andriacchi
    DOI: 10.1115/1.4001584
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The purpose of this study was to introduce a simple gait training method using real-time gait modification to reduce the peak knee adduction moment during walking by producing a subtle weight bearing shift to the medial side of the foot. The hypothesis of this study was that this weight shift could be achieved via either verbal instruction or an active feedback system, and that the weight shift would result in a reduction in the first peak knee adduction moment compared with the control tests. Nine individuals were tested during walking using two intervention methods: verbal instruction and an active feedback system placed on the right shoe. The first peak of the knee adduction moment for each condition was assessed using a motion capture system and force plate. The active feedback system significantly reduced (14.2%) the peak knee adduction moment relative to the control. This study demonstrated that a subtle weight bearing shift to the medial side of the foot produced with an active feedback system during walking reduced the first peak of the knee adduction moment and suggests the potential application of this method to slow the rate of progression of medial compartment knee osteoarthritis.
    keyword(s): Feedback , Knee , Osteoarthritis , Weight (Mass) AND Bearings ,
    • Download: (307.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Gait Modification via Verbal Instruction and an Active Feedback System to Reduce Peak Knee Adduction Moment

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/142585
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAriel V. Dowling
    contributor authorDavid S. Fisher
    contributor authorThomas P. Andriacchi
    date accessioned2017-05-09T00:36:33Z
    date available2017-05-09T00:36:33Z
    date copyrightJuly, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27152#071007_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142585
    description abstractThe purpose of this study was to introduce a simple gait training method using real-time gait modification to reduce the peak knee adduction moment during walking by producing a subtle weight bearing shift to the medial side of the foot. The hypothesis of this study was that this weight shift could be achieved via either verbal instruction or an active feedback system, and that the weight shift would result in a reduction in the first peak knee adduction moment compared with the control tests. Nine individuals were tested during walking using two intervention methods: verbal instruction and an active feedback system placed on the right shoe. The first peak of the knee adduction moment for each condition was assessed using a motion capture system and force plate. The active feedback system significantly reduced (14.2%) the peak knee adduction moment relative to the control. This study demonstrated that a subtle weight bearing shift to the medial side of the foot produced with an active feedback system during walking reduced the first peak of the knee adduction moment and suggests the potential application of this method to slow the rate of progression of medial compartment knee osteoarthritis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleGait Modification via Verbal Instruction and an Active Feedback System to Reduce Peak Knee Adduction Moment
    typeJournal Paper
    journal volume132
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4001584
    journal fristpage71007
    identifier eissn1528-8951
    keywordsFeedback
    keywordsKnee
    keywordsOsteoarthritis
    keywordsWeight (Mass) AND Bearings
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian