Abstract: Computational fluid dynamics (CFD) studies provide a valuable tool for evaluating the role of hemodynamics in vascular diseases such as cerebral aneurysms and atherosclerosis. However, such models necessarily only include isolated segments of the vasculature. In this work, we evaluate the influence of geometric approximations in vascular anatomy on hemodynamics in elastase induced saccular aneurysms in rabbits. One representative high aspect ratio (AR—height/neck width) aneurysm and one low AR aneurysm were created at the origin of the right common carotid artery in two New Zealand white rabbits. Three-dimensional (3D) reconstructions of the aneurysm and surrounding arteries were created using 3D rotational angiographic data. Five models with varying extents of neighboring vasculature were created for both the high and low AR cases. A reference model included the aneurysm sac, left common carotid artery (LCCA), aortic arch, and downstream trifurcation/quadrification. Three-dimensional, pulsatile CFD studies were performed and streamlines, wall shear stress (WSS), oscillatory shear index, and cross sectional velocity were compared between the models. The influence of the vascular domain on intra-aneurysmal hemodynamics varied between the low and high AR cases. For the high AR case, even a simple model including only the aneurysm, a small section of neighboring vasculature, and simple extensions captured the main features of the steamline and WSS distribution predicted by the reference model. However, the WSS distribution in the low AR case was more strongly influenced by the extent of vasculature. In particular, it was necessary to include the downstream quadrification and upstream LCCA to obtain good predictions of WSS. The findings in this work demonstrate the accuracy of CFD results can be compromised if insufficient neighboring vessels are included in studies of hemodynamics in elastase induced rabbit aneurysms. Consideration of aspect ratio, hemodynamic parameters of interest, and acceptable magnitude of error when selecting the vascular domain will increase reliability of the results while decreasing computational time.
keyword(s): Computational fluid dynamics , Hemodynamics , Aneurysms , Errors , Vessels AND Arches ,
|
Collections
Show full item record
| contributor author | Zijing Zeng | |
| contributor author | David F. Kallmes | |
| contributor author | Michael J. Durka | |
| contributor author | Yonghong Ding | |
| contributor author | Anne M. Robertson | |
| contributor author | Debra Lewis | |
| contributor author | Ramanathan Kadirvel | |
| date accessioned | 2017-05-09T00:36:29Z | |
| date available | 2017-05-09T00:36:29Z | |
| date copyright | September, 2010 | |
| date issued | 2010 | |
| identifier issn | 0148-0731 | |
| identifier other | JBENDY-27166#091009_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/142553 | |
| description abstract | Computational fluid dynamics (CFD) studies provide a valuable tool for evaluating the role of hemodynamics in vascular diseases such as cerebral aneurysms and atherosclerosis. However, such models necessarily only include isolated segments of the vasculature. In this work, we evaluate the influence of geometric approximations in vascular anatomy on hemodynamics in elastase induced saccular aneurysms in rabbits. One representative high aspect ratio (AR—height/neck width) aneurysm and one low AR aneurysm were created at the origin of the right common carotid artery in two New Zealand white rabbits. Three-dimensional (3D) reconstructions of the aneurysm and surrounding arteries were created using 3D rotational angiographic data. Five models with varying extents of neighboring vasculature were created for both the high and low AR cases. A reference model included the aneurysm sac, left common carotid artery (LCCA), aortic arch, and downstream trifurcation/quadrification. Three-dimensional, pulsatile CFD studies were performed and streamlines, wall shear stress (WSS), oscillatory shear index, and cross sectional velocity were compared between the models. The influence of the vascular domain on intra-aneurysmal hemodynamics varied between the low and high AR cases. For the high AR case, even a simple model including only the aneurysm, a small section of neighboring vasculature, and simple extensions captured the main features of the steamline and WSS distribution predicted by the reference model. However, the WSS distribution in the low AR case was more strongly influenced by the extent of vasculature. In particular, it was necessary to include the downstream quadrification and upstream LCCA to obtain good predictions of WSS. The findings in this work demonstrate the accuracy of CFD results can be compromised if insufficient neighboring vessels are included in studies of hemodynamics in elastase induced rabbit aneurysms. Consideration of aspect ratio, hemodynamic parameters of interest, and acceptable magnitude of error when selecting the vascular domain will increase reliability of the results while decreasing computational time. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Sensitivity of CFD Based Hemodynamic Results in Rabbit Aneurysm Models to Idealizations in Surrounding Vasculature | |
| type | Journal Paper | |
| journal volume | 132 | |
| journal issue | 9 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4001311 | |
| journal fristpage | 91009 | |
| identifier eissn | 1528-8951 | |
| keywords | Computational fluid dynamics | |
| keywords | Hemodynamics | |
| keywords | Aneurysms | |
| keywords | Errors | |
| keywords | Vessels AND Arches | |
| tree | Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 009 | |
| contenttype | Fulltext |