Show simple item record

contributor authorZijing Zeng
contributor authorDavid F. Kallmes
contributor authorMichael J. Durka
contributor authorYonghong Ding
contributor authorAnne M. Robertson
contributor authorDebra Lewis
contributor authorRamanathan Kadirvel
date accessioned2017-05-09T00:36:29Z
date available2017-05-09T00:36:29Z
date copyrightSeptember, 2010
date issued2010
identifier issn0148-0731
identifier otherJBENDY-27166#091009_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142553
description abstractComputational fluid dynamics (CFD) studies provide a valuable tool for evaluating the role of hemodynamics in vascular diseases such as cerebral aneurysms and atherosclerosis. However, such models necessarily only include isolated segments of the vasculature. In this work, we evaluate the influence of geometric approximations in vascular anatomy on hemodynamics in elastase induced saccular aneurysms in rabbits. One representative high aspect ratio (AR—height/neck width) aneurysm and one low AR aneurysm were created at the origin of the right common carotid artery in two New Zealand white rabbits. Three-dimensional (3D) reconstructions of the aneurysm and surrounding arteries were created using 3D rotational angiographic data. Five models with varying extents of neighboring vasculature were created for both the high and low AR cases. A reference model included the aneurysm sac, left common carotid artery (LCCA), aortic arch, and downstream trifurcation/quadrification. Three-dimensional, pulsatile CFD studies were performed and streamlines, wall shear stress (WSS), oscillatory shear index, and cross sectional velocity were compared between the models. The influence of the vascular domain on intra-aneurysmal hemodynamics varied between the low and high AR cases. For the high AR case, even a simple model including only the aneurysm, a small section of neighboring vasculature, and simple extensions captured the main features of the steamline and WSS distribution predicted by the reference model. However, the WSS distribution in the low AR case was more strongly influenced by the extent of vasculature. In particular, it was necessary to include the downstream quadrification and upstream LCCA to obtain good predictions of WSS. The findings in this work demonstrate the accuracy of CFD results can be compromised if insufficient neighboring vessels are included in studies of hemodynamics in elastase induced rabbit aneurysms. Consideration of aspect ratio, hemodynamic parameters of interest, and acceptable magnitude of error when selecting the vascular domain will increase reliability of the results while decreasing computational time.
publisherThe American Society of Mechanical Engineers (ASME)
titleSensitivity of CFD Based Hemodynamic Results in Rabbit Aneurysm Models to Idealizations in Surrounding Vasculature
typeJournal Paper
journal volume132
journal issue9
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4001311
journal fristpage91009
identifier eissn1528-8951
keywordsComputational fluid dynamics
keywordsHemodynamics
keywordsAneurysms
keywordsErrors
keywordsVessels AND Arches
treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record