YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Minimal Order Nonlinear Observer for Leak Detection

    Source: Journal of Dynamic Systems, Measurement, and Control:;2004:;volume( 126 ):;issue: 003::page 467
    Author:
    C. Verde
    DOI: 10.1115/1.1789533
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A method for leaks location in a pipeline, using sensors only at the extremes of the line is presented. The detection problem is solved, assuming a nonlinear fluid model of finite dimension with uncertainty in the leak position, and generating the residual with two minimal order nonlinear observers. Flow and pressure data at the beginning and at end of the line are considered as output and input of the system respectively. Since the proposed model satisfies (1) the condition to generate a residual, assuming at the most two leaks, and (2) the strong detectability fault property for each output component, two nonlinear robust filters with respect to a leak are designed to generate the residual. To simplify the residual evaluation and estimate the leak position, a static relationship between each component of the residual and the position error is derived. The main contribution of this paper is to take advantage of the residual equation with uncertainty to isolate a fault. The effectiveness of this approach is shown by a comparison with the practical method reported in [1] using results obtained from simulated and experimental data of a water pilot pipeline of 132 m long, with a diameter of 0.1 m and with a flow rate of 12 l/s.
    keyword(s): Pipelines , Leakage , Flow (Dynamics) , Errors AND Uncertainty ,
    • Download: (124.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Minimal Order Nonlinear Observer for Leak Detection

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/129753
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorC. Verde
    date accessioned2017-05-09T00:12:34Z
    date available2017-05-09T00:12:34Z
    date copyrightSeptember, 2004
    date issued2004
    identifier issn0022-0434
    identifier otherJDSMAA-26333#467_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/129753
    description abstractA method for leaks location in a pipeline, using sensors only at the extremes of the line is presented. The detection problem is solved, assuming a nonlinear fluid model of finite dimension with uncertainty in the leak position, and generating the residual with two minimal order nonlinear observers. Flow and pressure data at the beginning and at end of the line are considered as output and input of the system respectively. Since the proposed model satisfies (1) the condition to generate a residual, assuming at the most two leaks, and (2) the strong detectability fault property for each output component, two nonlinear robust filters with respect to a leak are designed to generate the residual. To simplify the residual evaluation and estimate the leak position, a static relationship between each component of the residual and the position error is derived. The main contribution of this paper is to take advantage of the residual equation with uncertainty to isolate a fault. The effectiveness of this approach is shown by a comparison with the practical method reported in [1] using results obtained from simulated and experimental data of a water pilot pipeline of 132 m long, with a diameter of 0.1 m and with a flow rate of 12 l/s.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMinimal Order Nonlinear Observer for Leak Detection
    typeJournal Paper
    journal volume126
    journal issue3
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.1789533
    journal fristpage467
    journal lastpage472
    identifier eissn1528-9028
    keywordsPipelines
    keywordsLeakage
    keywordsFlow (Dynamics)
    keywordsErrors AND Uncertainty
    treeJournal of Dynamic Systems, Measurement, and Control:;2004:;volume( 126 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian