description abstractIt is shown that the steady-state response such as temperature efficiency and number of heat transfer units have a direct relation with the dynamic response such as stability region of the PI control system. These relations are also explained by showing the physical meaning of the spatial weighting function presented by the authors. The theoretical results have also been confirmed by experiments. It is emphasized that the heat exchanger should be designed to have the excellent performance both at the steady state and the dynamic state.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Correlation Between Steady-State and Dynamic Response of a Counterflow Heat Exchanger
typeJournal Paper
journal volume111
journal issue1
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.3153009
journal fristpage115
journal lastpage118
identifier eissn1528-9028
treeJournal of Dynamic Systems, Measurement, and Control:;1989:;volume( 111 ):;issue: 001