YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Fluids Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Fluids Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Performance Characteristics of Elbow Flowmeters

    Source: Journal of Fluids Engineering:;1964:;volume( 086 ):;issue: 003::page 498
    Author:
    J. W. Murdock
    ,
    C. J. Foltz
    ,
    C. Gregory
    DOI: 10.1115/1.3653152
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The state of the art for metering flow with elbow meters is surveyed and past work is correlated with recent data from tests at the Naval Boiler and Turbine Laboratory. The elbow meter is compared with the orifice, Venturi, and flow nozzle and areas where research is needed are delineated.
    keyword(s): Flow (Dynamics) , Flowmeters , Boilers , Nozzles , Turbines , Venturi tubes AND Performance characterization ,
    • Download: (2.258Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance Characteristics of Elbow Flowmeters

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/100968
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorJ. W. Murdock
    contributor authorC. J. Foltz
    contributor authorC. Gregory
    date accessioned2017-05-08T23:22:11Z
    date available2017-05-08T23:22:11Z
    date copyrightSeptember, 1964
    date issued1964
    identifier issn0098-2202
    identifier otherJFEGA4-27255#498_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/100968
    description abstractThe state of the art for metering flow with elbow meters is surveyed and past work is correlated with recent data from tests at the Naval Boiler and Turbine Laboratory. The elbow meter is compared with the orifice, Venturi, and flow nozzle and areas where research is needed are delineated.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePerformance Characteristics of Elbow Flowmeters
    typeJournal Paper
    journal volume86
    journal issue3
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3653152
    journal fristpage498
    journal lastpage503
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsFlowmeters
    keywordsBoilers
    keywordsNozzles
    keywordsTurbines
    keywordsVenturi tubes AND Performance characterization
    treeJournal of Fluids Engineering:;1964:;volume( 086 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian