| dc.contributor.author | S. L. Collier | |
| dc.contributor.author | C. C. Hoerner | |
| dc.date.accessioned | 2017-05-08T23:15:20Z | |
| dc.date.available | 2017-05-08T23:15:20Z | |
| dc.date.copyright | March, 1983 | |
| dc.date.issued | 1983 | |
| dc.identifier.issn | 0195-0738 | |
| dc.identifier.other | JERTD2-26389#62_1.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/96992 | |
| dc.description.abstract | The important time for a check valve is the short period during which flow decelerates. The characteristics of this period are not well defined. The investigation suggests the use of deceleration (g) as a parameter, describes a test facility that provides a range of deceleration rates and presents results of tests at various g’s. This method couples the estimation of a system’s deceleration with the performance of the valve so that provisions can be made for the expected behavior and surge in a new installation or an improvement can be predicted for an existing problem situation. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | A Facility and Approach to Performance Test of Check Valves | |
| dc.type | Journal Paper | |
| dc.journal.volume | 105 | |
| dc.journal.issue | 1 | |
| dc.journal.title | Journal of Energy Resources Technology | |
| dc.identifier.doi | 10.1115/1.3230878 | |
| dc.journal.fristpage | 62 | |
| dc.journal.lastpage | 66 | |
| dc.identifier.eissn | 1528-8994 | |
| dc.keywords | Valves | |
| dc.keywords | Testing performance | |
| dc.keywords | Flow (Dynamics) | |
| dc.keywords | Surges AND Test facilities | |
| dc.tree | Journal of Energy Resources Technology:;1983:;volume( 105 ):;issue: 001 | |
| dc.contenttype | Fulltext | |