    A Facility and Approach to Performance Test of Check Valves

    Thumbnail
    View/Open
    JERTD2-26389#62_1.pdf (1.003Mb)
    Date
    1983
    Author
    S. L. Collier
    C. C. Hoerner
    Metadata
    Show full item record
    Abstract
    The important time for a check valve is the short period during which flow decelerates. The characteristics of this period are not well defined. The investigation suggests the use of deceleration (g) as a parameter, describes a test facility that provides a range of deceleration rates and presents results of tests at various g’s. This method couples the estimation of a system’s deceleration with the performance of the valve so that provisions can be made for the expected behavior and surge in a new installation or an improvement can be predicted for an existing problem situation.