Fracture Toughness of 4130 Quenched and Tempered Steel
Abstract
The fracture-energy criterion JIc was determined by the single specimen method on quenched and tempered 4130 steel used for tower anchor bars of high voltage transmission lines. A thermodynamic approach was used to rationalize JIc as a stable crack initiation criterion. Slow-bend testing was performed on three-point bend specimens of different dimensions. The effect of microstructure (martensite and bainite + ferrite) on the value of JIc is not significant. Specimen dimensions (1.5 × 3 × 15 cm; 2 × 4 × 20 cm) seem not to affect JIc values. Critical stretch zone width, WSZc , was evaluated on broken specimen halves using scanning electron microscopy. With some assumptions, relationships between WSZc , CTOD and JIc were established. Values of JIc calculated via WSZc compare favorably with JIc determined from a single specimen.