Show simple item record

dc.contributor.authorNeira-García, Jorge
dc.contributor.authorTorres, Andres
dc.contributor.authorSoliman, Ahmed
dc.contributor.authorArabian, Adam K.
dc.contributor.authorRastgaar, Mo
dc.date.accessioned2026-08-23T07:47:09Z
dc.date.available2026-08-23T07:47:09Z
dc.date.copyright2026/10/01
dc.date.issued2026
dc.identifier.issn1932-6181
dc.identifier.othermed-25-1229.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315601
dc.description.abstractAbstract. Force and moment measurements are critical for powered ankle-foot prostheses, with over 73% of prototypes incorporating such sensors. Hardware complexity, compatibility limitations, and cost barriers currently limit widespread clinical adoption. This work presents four contributions using the commercial strain gauge based instrumented pyramid adapter Europa+: (1) hardware integration compatible with standard prosthetic components and minimal added bulk (275 g, 37.5 mm height); (2) an adaptive zero drift compensation algorithm achieving stable calibration within 2–3 steps for continuous long-term operation; (3) physics-informed linear regression models for real-time ankle force and moment estimation; and (4) experimental validation with 8 nonamputee participants using a passive prosthesis, and a preliminary single-participant evaluation with a two-degree-of-freedom (2DOF) powered ankle-foot prosthesis in variable impedance closed-loop operation. Results demonstrate exceptional axial force estimation (RMSE=47 ± 20 N, R2=0.97 ± 0.03) and strong dorsi-plantar (DP) moment estimation (RMSE=5.7 ± 2.3 Nm, R2=0.87 ± 0.06) across passive prosthesis participants, and these remain valid for the powered prosthesis. Inversion-eversion (IE) moment estimation achieves RMSE=0.8 ± 0.2 Nm and R2=0.44 ± 0.16 on passive data, but performance improves when model parameters are derived from powered prosthesis gait with larger active IE range. This approach establishes a generalizable methodology applicable to strain gauge based instrumented pyramid adapters, offering a practical alternative to custom sensors while significantly reducing barriers to clinical implementation of ankle dynamics estimation in prosthetic applications.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnkle-Foot Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter
dc.typeJournal Paper
dc.journal.volume20
dc.journal.issue5
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4071784
dc.journal.fristpage105
dc.journal.lastpage114
dc.page10
dc.treeJournal of Medical Devices:;2026:;volume( 020 ):;issue:005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record