    Ankle-Foot Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter

    Thumbnail
    View/Open
    med-25-1229.pdf (1.853Mb)
    Date
    2026
    Author
    Neira-García, Jorge
    Torres, Andres
    Soliman, Ahmed
    Arabian, Adam K.
    Rastgaar, Mo
    Metadata
    Show full item record
    Abstract
    Abstract. Force and moment measurements are critical for powered ankle-foot prostheses, with over 73% of prototypes incorporating such sensors. Hardware complexity, compatibility limitations, and cost barriers currently limit widespread clinical adoption. This work presents four contributions using the commercial strain gauge based instrumented pyramid adapter Europa+: (1) hardware integration compatible with standard prosthetic components and minimal added bulk (275 g, 37.5 mm height); (2) an adaptive zero drift compensation algorithm achieving stable calibration within 2–3 steps for continuous long-term operation; (3) physics-informed linear regression models for real-time ankle force and moment estimation; and (4) experimental validation with 8 nonamputee participants using a passive prosthesis, and a preliminary single-participant evaluation with a two-degree-of-freedom (2DOF) powered ankle-foot prosthesis in variable impedance closed-loop operation. Results demonstrate exceptional axial force estimation (RMSE=47 ± 20 N, R2=0.97 ± 0.03) and strong dorsi-plantar (DP) moment estimation (RMSE=5.7 ± 2.3 Nm, R2=0.87 ± 0.06) across passive prosthesis participants, and these remain valid for the powered prosthesis. Inversion-eversion (IE) moment estimation achieves RMSE=0.8 ± 0.2 Nm and R2=0.44 ± 0.16 on passive data, but performance improves when model parameters are derived from powered prosthesis gait with larger active IE range. This approach establishes a generalizable methodology applicable to strain gauge based instrumented pyramid adapters, offering a practical alternative to custom sensors while significantly reducing barriers to clinical implementation of ankle dynamics estimation in prosthetic applications.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4315601
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV