• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Hat-Shaped Purlin-to-Rafter Screw Connections: Pull-Through Behavior and Design Implications

    Thumbnail
    View/Open
    JSENDH.STENG-14200.pdf (4.120Mb)
    Date
    2025
    Author
    Bishal Naik
    Lonavath Anusha Naik
    Prajwal Simkhada
    Mahendrakumar Mathialagu Madhavan
    Metadata
    Show full item record
    Abstract
    This study investigates the pull-through failure behavior of cold-formed steel (CFS) hat-shaped purlin-to-rafter screw connections. A total of 27 tests were conducted to analyze the effects of cross-section parameters such as top flange width, bottom flange width, and section thickness, along with diameter of the screw head. The experimental study employed three small-scale test setups: two-span purlin (Test setup A), cantilever purlin (Test setup B), and short-span purlin (Test setup C) to simulate wind uplift forces. Three-dimensional digital image correlation (3D-DIC) was used to determine the strain contours and verify the failure mechanisms. Additionally, an imperfection study was conducted to assess the distribution of load pattern to the adjacent screws of the hat-shaped purlin. Three different types of failure were identified: tearing-type, rupture-type, and bearing-type pull-through failure modes, which varied based on the thickness and width of the bottom flange of the hat sections. The study found existing design guidelines to be unconservative and proposed a modified design equation to better estimate the pull-through capacity of these connections. A reliability analysis was also conducted to determine appropriate resistance and safety factors for the proposed design equations. Cold-formed steel (CFS) residential construction is gaining popularity around the globe due to its high strength-to-weight ratio, versatility, and ease of construction. However, one of the primary objectives during design of CFS building is to protect the roof connection which are particularly vulnerable to cyclonic events. There exists a gap in the current design standards and existing literature for moderate-strength thicker (thickness, t>1.15  mm) hat-shaped purlin-to-rafter screw connections. This study addresses this critical issue by experimental testing equipped with 3D-DIC. The study led to the development of a more accurate and reliable design equation that considers section thickness (t) and diameter of the screw head (dw). Implementing these findings can enable construction of more resilient roofing systems that can better withstand high winds, thereby reducing the risk of progressive roof collapse. Integrating this new equation into building codes can significantly enhance the safety and reliability of CFS roofing systems, particularly in cyclone-prone regions areas such as India, Japan, and the coastal regions of the United States.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306783
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV