YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Hat-Shaped Purlin-to-Rafter Screw Connections: Pull-Through Behavior and Design Implications

    Source: Journal of Structural Engineering:;2025:;Volume ( 151 ):;issue: 007::page 04025083-1
    Author:
    Bishal Naik
    ,
    Lonavath Anusha Naik
    ,
    Prajwal Simkhada
    ,
    Mahendrakumar Mathialagu Madhavan
    DOI: 10.1061/JSENDH.STENG-14200
    Publisher: American Society of Civil Engineers
    Abstract: This study investigates the pull-through failure behavior of cold-formed steel (CFS) hat-shaped purlin-to-rafter screw connections. A total of 27 tests were conducted to analyze the effects of cross-section parameters such as top flange width, bottom flange width, and section thickness, along with diameter of the screw head. The experimental study employed three small-scale test setups: two-span purlin (Test setup A), cantilever purlin (Test setup B), and short-span purlin (Test setup C) to simulate wind uplift forces. Three-dimensional digital image correlation (3D-DIC) was used to determine the strain contours and verify the failure mechanisms. Additionally, an imperfection study was conducted to assess the distribution of load pattern to the adjacent screws of the hat-shaped purlin. Three different types of failure were identified: tearing-type, rupture-type, and bearing-type pull-through failure modes, which varied based on the thickness and width of the bottom flange of the hat sections. The study found existing design guidelines to be unconservative and proposed a modified design equation to better estimate the pull-through capacity of these connections. A reliability analysis was also conducted to determine appropriate resistance and safety factors for the proposed design equations. Cold-formed steel (CFS) residential construction is gaining popularity around the globe due to its high strength-to-weight ratio, versatility, and ease of construction. However, one of the primary objectives during design of CFS building is to protect the roof connection which are particularly vulnerable to cyclonic events. There exists a gap in the current design standards and existing literature for moderate-strength thicker (thickness, t>1.15  mm) hat-shaped purlin-to-rafter screw connections. This study addresses this critical issue by experimental testing equipped with 3D-DIC. The study led to the development of a more accurate and reliable design equation that considers section thickness (t) and diameter of the screw head (dw). Implementing these findings can enable construction of more resilient roofing systems that can better withstand high winds, thereby reducing the risk of progressive roof collapse. Integrating this new equation into building codes can significantly enhance the safety and reliability of CFS roofing systems, particularly in cyclone-prone regions areas such as India, Japan, and the coastal regions of the United States.
    • Download: (4.120Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Hat-Shaped Purlin-to-Rafter Screw Connections: Pull-Through Behavior and Design Implications

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306783
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorBishal Naik
    contributor authorLonavath Anusha Naik
    contributor authorPrajwal Simkhada
    contributor authorMahendrakumar Mathialagu Madhavan
    date accessioned2025-08-17T22:20:09Z
    date available2025-08-17T22:20:09Z
    date copyright7/1/2025 12:00:00 AM
    date issued2025
    identifier otherJSENDH.STENG-14200.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4306783
    description abstractThis study investigates the pull-through failure behavior of cold-formed steel (CFS) hat-shaped purlin-to-rafter screw connections. A total of 27 tests were conducted to analyze the effects of cross-section parameters such as top flange width, bottom flange width, and section thickness, along with diameter of the screw head. The experimental study employed three small-scale test setups: two-span purlin (Test setup A), cantilever purlin (Test setup B), and short-span purlin (Test setup C) to simulate wind uplift forces. Three-dimensional digital image correlation (3D-DIC) was used to determine the strain contours and verify the failure mechanisms. Additionally, an imperfection study was conducted to assess the distribution of load pattern to the adjacent screws of the hat-shaped purlin. Three different types of failure were identified: tearing-type, rupture-type, and bearing-type pull-through failure modes, which varied based on the thickness and width of the bottom flange of the hat sections. The study found existing design guidelines to be unconservative and proposed a modified design equation to better estimate the pull-through capacity of these connections. A reliability analysis was also conducted to determine appropriate resistance and safety factors for the proposed design equations. Cold-formed steel (CFS) residential construction is gaining popularity around the globe due to its high strength-to-weight ratio, versatility, and ease of construction. However, one of the primary objectives during design of CFS building is to protect the roof connection which are particularly vulnerable to cyclonic events. There exists a gap in the current design standards and existing literature for moderate-strength thicker (thickness, t>1.15  mm) hat-shaped purlin-to-rafter screw connections. This study addresses this critical issue by experimental testing equipped with 3D-DIC. The study led to the development of a more accurate and reliable design equation that considers section thickness (t) and diameter of the screw head (dw). Implementing these findings can enable construction of more resilient roofing systems that can better withstand high winds, thereby reducing the risk of progressive roof collapse. Integrating this new equation into building codes can significantly enhance the safety and reliability of CFS roofing systems, particularly in cyclone-prone regions areas such as India, Japan, and the coastal regions of the United States.
    publisherAmerican Society of Civil Engineers
    titleHat-Shaped Purlin-to-Rafter Screw Connections: Pull-Through Behavior and Design Implications
    typeJournal Article
    journal volume151
    journal issue7
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-14200
    journal fristpage04025083-1
    journal lastpage04025083-18
    page18
    treeJournal of Structural Engineering:;2025:;Volume ( 151 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش