• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design, Evaluation, and Implementation of a Novel Magnetic Resonance Imaging-Compatible Physiologic Loading Simulator for Ex-Vivo Joints

    Thumbnail
    View/Open
    bio_147_01_011008.pdf (5.007Mb)
    Date
    2024
    Author
    Espinosa Maldonado, Alvaro A.
    Dolovich, Allan T.
    Johnston, James D.
    McWalter, Emily J.
    Metadata
    Show full item record
    Abstract
    Quantitative magnetic resonance imaging (qMRI), in combination with mechanical testing, offers potential to investigate how loading (e.g., from daily physical exercise) is related to joint and tissue function. However, current testing devices compatible with magnetic resonance imaging (MRI) are often limited to uniaxial compression, often applying low loads, or loading individual tissues (instead of multiple), while more complex simulators do not facilitate MRI. Hence, in this work, we designed, built and tested (N = 1) an MRI-compatible multi-axial load-control system, which enables scanning cadaveric joints (healthy or pathologic) loaded to physiologically relevant levels. Testing involved estimating and validating physiologic loading conditions before implementing them experimentally on cadaver knees to simulate and image gait loading (stance and swing). The resulting design consisted of a portable loading device featuring pneumatic actuators to reach a combined loading scenario, including axial compression (≤2.5 kN), shear (≤1 kN), bending (≤30 N·m) and muscle tension. Initial laboratory testing was carried out; specifically, the device was instrumented with force and pressure sensors to evaluate loading and contact response repeatability in one cadaver knee specimen. This loading system was able to simulate healthy or pathologic gait with reasonable repeatability (e.g., 1.23–2.91% coefficient of variation for axial compression), comparable to current state-of-the-art simulators, leading to generally consistent contact responses. Contact measurements demonstrated a tibiofemoral to patellofemoral load transfer with knee flexion and large contact pressures concentrated over small sites between the femoral cartilage and menisci, agreeing with experimental studies and numerical simulations in the literature.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305171
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV