Show simple item record

dc.contributor.authorDuan, Yuzhou
dc.contributor.authorLing, Jie
dc.contributor.authorZhu, Yuchuan
dc.date.accessioned2024-12-24T19:14:51Z
dc.date.available2024-12-24T19:14:51Z
dc.date.copyright8/1/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn1932-6181
dc.identifier.othermed_018_03_034501.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303576
dc.description.abstractRobotic-assisted lumbar puncture (LP) has been explored in recent years. The most important step in this procedure is accurately and safely puncturing the spinal membrane (dura mater) based on an automatic needle insertion device (NID). Piezoactuated NID has shown its advantages with high precision and compact structure. Soft control of the NID is important for insertion safety; however, for stick-slip piezoactuated NID, there are few studies due to the complex mechanism of stick-slip motion. Here, a modeling and admittance control method for a proposed stick-slip piezoactuated NID is proposed for safe puncture of the spinal membrane. To analytically model the NID, the compliant mechanism (CM) in the NID is reduced to a second-order system. The stick-slip friction and the spinal membrane are modeled based on the LuGre model and the Hunt–Crossley model, respectively. Based on these models, an admittance controller (AC) for the proposed NID is established to realize the precise control of the position and the safety protection against puncture errors. Simulations and preliminary experiments based on a prototype of the NID and a phantom of the spinal membrane were carried out to test the proposed modeling and control method. Results show that the proposed NID with AC has a maximum insertion error of 0.62 mm and the insertion depth decays by 80% when an unexpected force is applied. Therefore, the proposed model and control method have the potential to be used in real LP procedures by further development.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleModeling and Admittance Control of a Piezoactuated Needle Insertion Device for Safe Puncture of Spinal Membranes
dc.typeJournal Paper
dc.journal.volume18
dc.journal.issue3
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4066045
dc.journal.fristpage34501-1
dc.journal.lastpage34501-6
dc.page6
dc.treeJournal of Medical Devices:;2024:;volume( 018 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record