• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Modeling and Admittance Control of a Piezoactuated Needle Insertion Device for Safe Puncture of Spinal Membranes

    Thumbnail
    View/Open
    med_018_03_034501.pdf (1.685Mb)
    Date
    2024
    Author
    Duan, Yuzhou
    Ling, Jie
    Zhu, Yuchuan
    Metadata
    Show full item record
    Abstract
    Robotic-assisted lumbar puncture (LP) has been explored in recent years. The most important step in this procedure is accurately and safely puncturing the spinal membrane (dura mater) based on an automatic needle insertion device (NID). Piezoactuated NID has shown its advantages with high precision and compact structure. Soft control of the NID is important for insertion safety; however, for stick-slip piezoactuated NID, there are few studies due to the complex mechanism of stick-slip motion. Here, a modeling and admittance control method for a proposed stick-slip piezoactuated NID is proposed for safe puncture of the spinal membrane. To analytically model the NID, the compliant mechanism (CM) in the NID is reduced to a second-order system. The stick-slip friction and the spinal membrane are modeled based on the LuGre model and the Hunt–Crossley model, respectively. Based on these models, an admittance controller (AC) for the proposed NID is established to realize the precise control of the position and the safety protection against puncture errors. Simulations and preliminary experiments based on a prototype of the NID and a phantom of the spinal membrane were carried out to test the proposed modeling and control method. Results show that the proposed NID with AC has a maximum insertion error of 0.62 mm and the insertion depth decays by 80% when an unexpected force is applied. Therefore, the proposed model and control method have the potential to be used in real LP procedures by further development.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4303576
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV