• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Performance of Steel Beams to Diamond-Shaped Concrete-Filled Steel Tube Column Connections: Concept and Validation

    Thumbnail
    View/Open
    10.1061-JSENDH.STENG-11555.pdf (5.924Mb)
    Date
    2023/12/01
    Author
    Redhwan M. Algobahi
    Mohamed F. M. Fahmy
    Mohamed Abdel-Basset Abdo
    Metadata
    Show full item record
    Abstract
    The brittle behavior traditional directly welded connections of steel beams to concrete-filled steel tube columns is caused primarily by excessive out-of-plane deformation of the tube walls at the level of the beam tension flange. To address this issue, this study proposes a reference connection that involves fillet welding a built-up steel beam directly to the corner of a diamond-shaped concrete-filled steel tube (DCFST) column. Two options are suggested for enhancing the seismic performance of the reference connection: a predrilled hole with a 12-mm diameter at the midwidth of each beam flange, or a rib stiffener reinforcement on the outside of each beam flange. The two proposed specimens and a traditional directly welded connection were subassembled and investigated experimentally. The results showed that the reference DCFST connection significantly improved the seismic response of the directly welded connection in terms of initial stiffness, strength, ductility, and energy-dissipating capacity. Specifically, the initial stiffness and strength capacity increased by over 150% compared with that of the traditional connection counterpart. Furthermore, the rib stiffeners contributed to further enhancement of the seismic response by shifting the beam plastic hinge away from the column face. Overall, these findings suggest that the use of DCFST connections is reliable for composite moment-resisting frames (C-MRFs), and the proposed enhancements can improve the seismic performance of these connections significantly.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296209
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV