    Assessment of Storage Sizing for Solar Tower Plants Using Model-Predictive Control for Dispatch Planning

    Thumbnail
    View/Open
    sol_146_4_041005.pdf (1.375Mb)
    Date
    2024
    Author
    Mohammadzadeh, Navid
    Truong-Ba, Huy
    Picotti, Giovanni
    Cholette, Michael E.
    Metadata
    Show full item record
    Abstract
    Solar tower with thermal energy storage (ST-TES) represents a promising technology for large-scale exploitation of solar irradiation for electricity generation. A ST-TES has the potential to extend electricity generation to more favorable conditions, such as high electricity prices. The size of TES, however, constrains the flexibility of dispatching, especially when there is significant uncertainty in forecasts of solar irradiation and electricity prices. This study explores the impact of TES size when the plant uses model-predictive control (MPC) for dispatch planning. The performance of MPC is benchmarked against one perfect knowledge (PK) and two day-ahead strategies. The optimal achievable profit for each TES size is determined using the PK strategy. An analysis is conducted to evaluate the relative profit losses for all the other simulated strategies compared to the PK strategy. A case study is conducted for a hypothetical 115 MWe ST-TES in South Australia. For January and August, 100 tests are performed for each dispatch policy, with the TES size varying from 6 to 14 h. The revenue evaluation is conducted with both fixed and wholesale spot prices. The analysis shows that MPC-aided dispatching enables the adoption of a smaller TES compared to day-ahead policies while maintaining the same expected profit. The resulting TES size reduction from 14 to 10 h translates into approximately up to $45.4 million in capital cost savings. The findings of this study can inform the ST-TES plant’s design procedures and facilitate negotiations for electricity sales contracts.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295836
    Collections
    • Journal of Solar Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV