    Enhancing Inhalation Drug Delivery: A Comparative Study and Design Optimization of a Novel Valved Holding Chamber

    Thumbnail
    View/Open
    bio_146_04_041002.pdf (2.811Mb)
    Date
    2024
    Author
    Azimi, Shahab
    Arzanpour, Siamak
    Metadata
    Show full item record
    Abstract
    This paper presents an innovative approach to the design optimization of valved holding chambers (VHCs), crucial devices for aerosol drug delivery. We present the design of an optimal cylindrical VHC body and introduce a novel valve based on particle impaction theory. The research combines computational simulations and physical experiments to assess the performance of various VHCs, with a special focus on the deposition patterns of medication particles within these devices. The methodology incorporates both experimental and simulation approaches to validate the reliability of the simulation. Emphasis is placed on the deposition patterns observed on the VHC walls and the classification of fine and large particles for salbutamol sulfate particles. The study reveals the superior efficacy of our valve design in separating particles compared to commercially available VHCs. In standard conditions, our valve design allows over 95% of particles under 7 μm to pass through while effectively filtering those larger than 8 μm. The optimized body design accomplishes a 60% particle mass flow fraction at the outlet and an average particle size reduction of 58.5%. When compared numerically in terms of size reduction, the optimal design outperforms the two commercially available VHCs selected. This study provides valuable insights into the optimization of VHC design, offering significant potential for improved aerosol drug delivery. Our findings demonstrate a new path forward for future studies, aiming to further optimize the design and performance of VHCs for enhanced pulmonary drug delivery.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295375
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV