• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Fluids Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Fluids Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Aerodynamic Analysis of Low-Pressure Axial Fans Installed in Parallel

    Thumbnail
    View/Open
    fe_146_05_051204.pdf (4.617Mb)
    Date
    2024
    Author
    Ghosh, Debarshee
    Andersson, Niklas
    Etemad, Sassan
    Metadata
    Show full item record
    Abstract
    Ducted rotor-only low-pressure axial fans play an integral role in automotive thermal management. The tightly packed under-hood region and down-stream heat-exchanger shape limit the fan diameter. In order to circumvent this limitation, multiple cooling fans of small diameters are tightly packaged and placed in parallel. Currently, there is limited scientific work, that study the aerodynamics of low-pressure axial fans when installed in parallel. This work aims to quantify the aerodynamic performance and the flow-field as a result of installing low-pressure axial fans in parallel through computational fluid dynamics (CFD). Publicly available experimental data from Friedrich-Alexander University is used for the validation of the numerical setup. Three-dimensional, full-annulus, unsteady Reynolds-averaged Navier‐Stokes (URANS) analysis has been performed for both a single-fan and two-fans installed in parallel and their respective aerodynamic performance has been compared for the operation condition identified as the best efficiency point in experiments. Only small differences are observed in the overall aerodynamic performance of the two-fans in parallel compared to a single-fan. A circumferential nonuniformity in the form of a local high-pressure zone at the inlet of the fan is observed when the two-fans are placed in parallel. The resulting circumferential nonuniformity is quantified, both in space and time. A strong correlation is found between the pressure fields of the two-fans installed in parallel.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295126
    Collections
    • Journal of Fluids Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV