Show simple item record

dc.contributor.authorKhened, Vineet
dc.contributor.authorDhok, Kanad
dc.contributor.authorPradhan, Mahesh
dc.contributor.authorDhatrak, Pankaj
dc.date.accessioned2023-11-29T19:08:13Z
dc.date.available2023-11-29T19:08:13Z
dc.date.copyright3/8/2023 12:00:00 AM
dc.date.issued3/8/2023 12:00:00 AM
dc.date.issued2023-03-08
dc.identifier.issn2572-7958
dc.identifier.otherjesmdt_006_03_030901.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294603
dc.description.abstractDental implants are surgically implanted into the patient's jaw to replace a missing tooth. The implant should have adequate time to integrate with bone before being subjected to masticatory force to avoid early failure. Resonance frequency analysis (RFA) is one of the approaches for determining an implant system's primary stability in terms of micromotion. This research aims to create a two degrees-of-freedom (DOF) mathematical model for dental prostheses based on the vibroacoustic RFA approach. In vibroacoustic system, a loudspeaker or buzzer is used as an input and the displacement of implant is measured using RFA. A sinusoidal force is used which produces a combination of translational and rotational motion of the implant system. While adjusting the input frequency from 4000 to 12,000 Hz, is used with the help of matlab which later computes the implant system's subsequent micromotion and resonance frequency. matlab is used to visualize the resonance frequency, which is 6658.38 Hz in case of rotational motion and 8138 Hz in translational motion. The micromotion was 1.2692 × 10−11 m in case of translational motion and 6.91088 × 10−9 radians in case of rotational motion. When there is less micromotion, a higher resonance frequency suggests more excellent osseointegration. For the evaluation of implant stability, a mathematical model is a primary approach that can be implemented to design a stability device using vibroacoustic RFA.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEvaluation of Resonance Frequency and Micromotion to Achieve Implant Stability Using Vibroacoustic Resonance Frequency Analysis: A Mathematical Model
dc.typeJournal Paper
dc.journal.volume6
dc.journal.issue3
dc.journal.titleJournal of Engineering and Science in Medical Diagnostics and Therapy
dc.identifier.doi10.1115/1.4056951
dc.journal.fristpage30901-1
dc.journal.lastpage30901-7
dc.page7
dc.treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2023:;volume( 006 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record