    Evaluation of Resonance Frequency and Micromotion to Achieve Implant Stability Using Vibroacoustic Resonance Frequency Analysis: A Mathematical Model

    Thumbnail
    View/Open
    jesmdt_006_03_030901.pdf (1.149Mb)
    Date
    3/8/2023 1
    2023-03-08
    Author
    Khened, Vineet
    Dhok, Kanad
    Pradhan, Mahesh
    Dhatrak, Pankaj
    Metadata
    Show full item record
    Abstract
    Dental implants are surgically implanted into the patient's jaw to replace a missing tooth. The implant should have adequate time to integrate with bone before being subjected to masticatory force to avoid early failure. Resonance frequency analysis (RFA) is one of the approaches for determining an implant system's primary stability in terms of micromotion. This research aims to create a two degrees-of-freedom (DOF) mathematical model for dental prostheses based on the vibroacoustic RFA approach. In vibroacoustic system, a loudspeaker or buzzer is used as an input and the displacement of implant is measured using RFA. A sinusoidal force is used which produces a combination of translational and rotational motion of the implant system. While adjusting the input frequency from 4000 to 12,000 Hz, is used with the help of matlab which later computes the implant system's subsequent micromotion and resonance frequency. matlab is used to visualize the resonance frequency, which is 6658.38 Hz in case of rotational motion and 8138 Hz in translational motion. The micromotion was 1.2692 × 10−11 m in case of translational motion and 6.91088 × 10−9 radians in case of rotational motion. When there is less micromotion, a higher resonance frequency suggests more excellent osseointegration. For the evaluation of implant stability, a mathematical model is a primary approach that can be implemented to design a stability device using vibroacoustic RFA.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294603
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV