• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Impact of Blood Rheology on Transition to Turbulence and Wall Vibration Downstream of a Stenosis

    Thumbnail
    View/Open
    bio_145_04_041001.pdf (1.483Mb)
    Date
    12/5/2022
    2022-12-05
    Author
    Pinto Costa, Rayanne
    Nwotchouang, Blaise Simplice Talla
    Yao, Junyao
    Biswas, Dipankar
    Casey, David
    McKenzie, Ruel
    Sebastian, Frederick
    Amini, Rouzbeh
    Steinman, David A.
    Loth, Francis
    Metadata
    Show full item record
    Abstract
    Previous experimental flow studies have demonstrated a delay (∼20%) in transition to turbulence for whole blood compared to a Newtonian analog fluid in both a straight pipe and eccentric stenosis model with ridged walls. The impact of wall compliance on the transition to turbulence of blood compared to Newtonian analog and on wall vibration is unknown. The present study employed flexible walls downstream of an eccentric stenosis model and examined the wall vibration during the transition to turbulence with whole blood and a Newtonian analog. Measurements of tube wall vibration velocity (WVV) were used as an indicator of the turbulence level within the flexible tube. WVV was measured at 5, 10, and 15 diameters downstream of the stenosis using a laser Doppler vibrometer at Reynolds numbers 0, 200, 300, 350, 400, 450, 500, 550, 600, 650, 700, and 750. The root mean squares (RMS) of the measured WVV were utilized as an indirect measure of fluid velocity fluctuations present at that location, and hence, an indicator of transition to turbulence. WVV RMS was near-constant until approximately Reynolds number 400. It increased monotonically with Reynolds number for both whole blood and the Newtonian fluid. No differences in the transition to turbulence were observed between whole blood and the Newtonian fluid, as the WVV RMS curves were remarkably similar in shape. This result suggests that rheology had minimal impact on the WVV downstream of a stenosis for transition to turbulence since the fluids had a similar level of vibration.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294300
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV