• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Investigation of the Shear Behavior of Slender Continuous Steel–Concrete Composite Girders in Hogging Moment

    Thumbnail
    View/Open
    JSENDH.STENG-11537.pdf (2.912Mb)
    Date
    11/3/2022
    Author
    Pengfei Men
    Jin Di
    Fengjiang Qin
    Yi Su
    Metadata
    Show full item record
    Abstract
    Predicting the shear strength of composite girders is critical in improving the efficiency of bridge engineering. To investigate the shear behavior of slender continuous steel–concrete composite girders commonly employed in bridge structures in hogging moment regions, experiments were conducted on three slender two-span continuous composite girders with the moment/shear ratio of the section at the interior support as the test parameter. The test results showed that all three continuous girders experienced web shear buckling and shear failure of the concrete slabs. As the moment/shear ratio increased from 0.59 to 0.89, the shear strength decreased by 12.5%. The shear strengths of the specimens were evaluated using the design methods in the existing AASHTO and Eurocode 4 codes, as well as the one proposed by Liang et al. They were 21%–38% and 33%–50% higher than those calculated by the existing AASHTO and EC4 codes, respectively, indicating that the two codes yielded very conservative results. A numerical study was conducted using the nonlinear finite element model validated by the test results. The results showed that the moment/shear ratio, concrete slab thickness, and web height-to-thickness ratio all significantly influence the shear strength; the codes will yield increasingly conservative predictions with the increase of concrete slab thickness or web height-to-thickness ratio. Both test and numerical results revealed that the design method proposed by Liang et al. can better predict the shear strength of continuous composite girders in hogging moment regions.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294098
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV