YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Investigation of the Shear Behavior of Slender Continuous Steel–Concrete Composite Girders in Hogging Moment

    Source: Journal of Structural Engineering:;2022:;Volume ( 149 ):;issue: 001::page 04022218-1
    Author:
    Pengfei Men
    ,
    Jin Di
    ,
    Fengjiang Qin
    ,
    Yi Su
    DOI: 10.1061/JSENDH.STENG-11537
    Publisher: ASCE
    Abstract: Predicting the shear strength of composite girders is critical in improving the efficiency of bridge engineering. To investigate the shear behavior of slender continuous steel–concrete composite girders commonly employed in bridge structures in hogging moment regions, experiments were conducted on three slender two-span continuous composite girders with the moment/shear ratio of the section at the interior support as the test parameter. The test results showed that all three continuous girders experienced web shear buckling and shear failure of the concrete slabs. As the moment/shear ratio increased from 0.59 to 0.89, the shear strength decreased by 12.5%. The shear strengths of the specimens were evaluated using the design methods in the existing AASHTO and Eurocode 4 codes, as well as the one proposed by Liang et al. They were 21%–38% and 33%–50% higher than those calculated by the existing AASHTO and EC4 codes, respectively, indicating that the two codes yielded very conservative results. A numerical study was conducted using the nonlinear finite element model validated by the test results. The results showed that the moment/shear ratio, concrete slab thickness, and web height-to-thickness ratio all significantly influence the shear strength; the codes will yield increasingly conservative predictions with the increase of concrete slab thickness or web height-to-thickness ratio. Both test and numerical results revealed that the design method proposed by Liang et al. can better predict the shear strength of continuous composite girders in hogging moment regions.
    • Download: (2.912Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Investigation of the Shear Behavior of Slender Continuous Steel–Concrete Composite Girders in Hogging Moment

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4294098
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorPengfei Men
    contributor authorJin Di
    contributor authorFengjiang Qin
    contributor authorYi Su
    date accessioned2023-11-28T00:12:07Z
    date available2023-11-28T00:12:07Z
    date issued11/3/2022 12:00:00 AM
    identifier otherJSENDH.STENG-11537.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294098
    description abstractPredicting the shear strength of composite girders is critical in improving the efficiency of bridge engineering. To investigate the shear behavior of slender continuous steel–concrete composite girders commonly employed in bridge structures in hogging moment regions, experiments were conducted on three slender two-span continuous composite girders with the moment/shear ratio of the section at the interior support as the test parameter. The test results showed that all three continuous girders experienced web shear buckling and shear failure of the concrete slabs. As the moment/shear ratio increased from 0.59 to 0.89, the shear strength decreased by 12.5%. The shear strengths of the specimens were evaluated using the design methods in the existing AASHTO and Eurocode 4 codes, as well as the one proposed by Liang et al. They were 21%–38% and 33%–50% higher than those calculated by the existing AASHTO and EC4 codes, respectively, indicating that the two codes yielded very conservative results. A numerical study was conducted using the nonlinear finite element model validated by the test results. The results showed that the moment/shear ratio, concrete slab thickness, and web height-to-thickness ratio all significantly influence the shear strength; the codes will yield increasingly conservative predictions with the increase of concrete slab thickness or web height-to-thickness ratio. Both test and numerical results revealed that the design method proposed by Liang et al. can better predict the shear strength of continuous composite girders in hogging moment regions.
    publisherASCE
    titleExperimental Investigation of the Shear Behavior of Slender Continuous Steel–Concrete Composite Girders in Hogging Moment
    typeJournal Article
    journal volume149
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-11537
    journal fristpage04022218-1
    journal lastpage04022218-16
    page16
    treeJournal of Structural Engineering:;2022:;Volume ( 149 ):;issue: 001
    contenttypeFulltext