    Kinetic Temperature of Structures for Resilience, Instability, and Failure Analysis of Building Systems

    Thumbnail
    View/Open
    JENMDT.EMENG-6860.pdf (1.006Mb)
    Date
    2023/02/01
    Author
    Konstantinos Keremidis
    Tina Vartziotis
    Franz-Josef Ulm
    Metadata
    Show full item record
    Abstract
    From theory, calibration and application of the equipartition theorem of statistical physics to structural failure and instability analysis, we introduce the kinetic temperature of structures as an order parameter to ascertain equilibrium and out-of-equilibrium states in structural mechanics. Set within the framework of molecular dynamics-based structural mechanics, this is achieved by connecting the set of momentum balance equations to an outside bath reservoir maintained at a reference temperature history through the Nosé-Hoover thermostat. The problem thus comes down to solving the momentum balance equation with a dissipative mass damping term, which evolves in function of the difference in temperature between the structure’s kinetic temperature/energy and the bath temperature. Following the Zeroth Law of Thermodynamics, it is recognized that a structure is in (thermal) equilibrium as long as the structure’s kinetic temperature attains the bath temperature; whereas it is out-of-equilibrium when the open system (structure plus bath) exhibits a sustained temperature difference. In this case, the structure has exhausted its fluctuation-dissipation capacity, which is indicative—for structures—of a progressive failure and instability. The implementation of the kinetic temperature as an order parameter in structural failure and instability analysis is illustrated for a prototype five-storey building subject to excessive wind and fire loads. It is suggested that the proposed order parameter becomes an integral part of the structural engineering toolbox for resilience studies of buildings and structures.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292643
    Collections
    • Journal of Engineering Mechanics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV