Investigations of In-Plane Fluidelastic Instability in a Multispan U-Bend Tube Array—Part II: Tests in Two-Phase Flow
View/ Open
Date
2023Author
Feenstra, Paul
Sawadogo, Teguewinde
Smith, Bruce
Janzen, Victor
McLellan, Anne
Cothron, Helen
Kil, Sean
Metadata
Show full item recordAbstract
Tests to study fluidelastic instability (FEI) in an array of U-bend tubes were recently completed in the multispan U-Bend test rig at Canadian Nuclear Laboratories. These tests were sponsored by the Electric Power Research Institute and were designed to study in-plane fluid elastic instability of steam generator tubes in two-phase cross flow. This instability mechanism was first observed in previous experiments by Atomic Energy of Canada Limited. This mechanism was not thought to be a serious practical concern until 2012 when it caused severe damage to tubes in a new replacement steam-generator in a nuclear power plant in the United States. In this study, tests were conducted both with flows of air and two-phase liquid/vapor Refrigerant 134a. The tube bundle consisted of 22 flexible U-bend tubes supported by a configurable flat-bar arrangement. Testing focused on the effects of support geometry and tube-to-support interaction. Data were recorded from 33 dynamic signals from accelerometers, displacement probes, force transducers, and void-fraction probes. Part I of this two-part series presented results of air tests. Part II presents results of tests using two-phase Freon refrigerant (R-134a) as the working fluid.