• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Joint Coordinate System Using Functional Axes Achieves Clinically Meaningful Kinematics of the Tibiofemoral Joint as Compared to the International Society of Biomechanics Recommendation

    Thumbnail
    View/Open
    bio_145_05_051005.pdf (1.989Mb)
    Date
    2023
    Author
    Pourtabib, Joe
    Hull, M. L.
    Metadata
    Show full item record
    Abstract
    Quantification of clinically meaningful tibiofemoral motions requires a joint coordinate system (JCS) with motions free from kinematic crosstalk errors. The objectives were to use a JCS with literature-backed functional axes (FUNC) and a JCS recommended by the International Society of Biomechanics (ISB) to determine tibiofemoral kinematics of the native (i.e., healthy) knee, determine variability associated with each JCS, and determine whether the FUNC JCS significantly reduced kinematic crosstalk errors compared to the ISB JCS. Based on a kinematic model consisting of a three-cylindric joint chain, the FUNC JCS included functional flexion–extension (F–E) and internal-external (I–E) tibial rotation axes. In contrast, the ISB JCS included F–E and I–E axes defined using anatomic landmarks. Single-plane fluoroscopic images in 13 subjects performing a weighted deep knee bend were analyzed. Tibiofemoral kinematics using the FUNC JCS fell within the physiological range of motion in all six degrees-of-freedom. Internal tibial rotation averaged 13 deg for the FUNC JCS versus 10 deg for the ISB JCS and motions in the other four degrees-of-freedom (collectively termed off-axis motions) were minimal as expected based on biomechanical constraints. Off-axis motions for the ISB JCS were significantly greater; maximum valgus rotation was 4 deg and maximum anterior and distraction translations were 9 mm and 25 mm, respectively, which is not physiologic. Variabilities in off-axis motions were significantly greater with the ISB JCS (p < 0.0002). The FUNC JCS achieved clinically meaningful kinematics by significantly reducing kinematic crosstalk errors and is the more suitable coordinate system for quantifying tibiofemoral motions.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292355
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV