Show simple item record

dc.contributor.authorWang, Yan;Wang, Hewu;Gao, Qing;Zhang, Xiaohang;Zhang, Xilong;Liu, Zunmin
dc.date.accessioned2023-04-06T12:54:11Z
dc.date.available2023-04-06T12:54:11Z
dc.date.copyright9/22/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn23816872
dc.identifier.otherjeecs_20_3_031002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288732
dc.description.abstractThe heat pump system employed with a dual evaporator for battery cooling coupled with cabin comfort is an innovative thermal management method. It can be inferred that the refrigerant thermal load distribution can trigger temperature fluctuations for the thermal performance of both battery and cabin. To tradeoff between the thermal management demands of battery and cabin, this study proposed a strategy to promote the decreasing of battery temperature and to ensure battery thermal uniformity with a higher priority. Hence, a transient refrigerant flowrate distribution scheme with a minimum flowrate to satisfy battery thermal demands was researched. According to the proposed method, this study investigated three cases of electric vehicle (EV) acceleration conditions with different driving speed levels. The results indicated that, with the proposed method, the battery module average temperature can be lower than 303 K with a 4–8 K maximum temperature difference. Additionally, the cabin airsupply average temperature would range from 285 K to 287 K, the virtual thermal manikin face and leg temperature range from 296 K to 302 K, and the cabin rear zone temperature ranges from 296 K to 298 K for three acceleration driving conditions. To evaluate the EV cabin thermal comfort, the predicted mean vote (PMV) index was introduced by the American Society of Heating, Refrigerating and AirConditioning Engineers (ASHARE). It also provides evidence that with the proposed method, the thermal comfort in the EV cabin can satisfy the ASHARE proposed value range of ±0.5. The results showed a significant reduction in the temperature fluctuations for cabin thermal comfort and battery thermal management thermal controlling. It offers a satisfactory reference for the refrigerant thermal load distribution strategy applied with the heat pump system connected to the battery and cabin by the dual evaporator.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleRefrigerant Flow Distribution Research for Battery Cooling Coupled With Cabin Comfort Based on DualEvaporator Heat Pump System for Electric Vehicle Acceleration
dc.typeJournal Paper
dc.journal.volume20
dc.journal.issue3
dc.journal.titleJournal of Electrochemical Energy Conversion and Storage
dc.identifier.doi10.1115/1.4055274
dc.journal.fristpage31002
dc.journal.lastpage3100215
dc.page15
dc.treeJournal of Electrochemical Energy Conversion and Storage:;2022:;volume( 020 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record