• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Electrochemical Energy Conversion and Storage
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Electrochemical Energy Conversion and Storage
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Refrigerant Flow Distribution Research for Battery Cooling Coupled With Cabin Comfort Based on DualEvaporator Heat Pump System for Electric Vehicle Acceleration

    Thumbnail
    View/Open
    jeecs_20_3_031002.pdf (1.726Mb)
    Date
    2022
    Author
    Wang, Yan;Wang, Hewu;Gao, Qing;Zhang, Xiaohang;Zhang, Xilong;Liu, Zunmin
    Metadata
    Show full item record
    Abstract
    The heat pump system employed with a dual evaporator for battery cooling coupled with cabin comfort is an innovative thermal management method. It can be inferred that the refrigerant thermal load distribution can trigger temperature fluctuations for the thermal performance of both battery and cabin. To tradeoff between the thermal management demands of battery and cabin, this study proposed a strategy to promote the decreasing of battery temperature and to ensure battery thermal uniformity with a higher priority. Hence, a transient refrigerant flowrate distribution scheme with a minimum flowrate to satisfy battery thermal demands was researched. According to the proposed method, this study investigated three cases of electric vehicle (EV) acceleration conditions with different driving speed levels. The results indicated that, with the proposed method, the battery module average temperature can be lower than 303 K with a 4–8 K maximum temperature difference. Additionally, the cabin airsupply average temperature would range from 285 K to 287 K, the virtual thermal manikin face and leg temperature range from 296 K to 302 K, and the cabin rear zone temperature ranges from 296 K to 298 K for three acceleration driving conditions. To evaluate the EV cabin thermal comfort, the predicted mean vote (PMV) index was introduced by the American Society of Heating, Refrigerating and AirConditioning Engineers (ASHARE). It also provides evidence that with the proposed method, the thermal comfort in the EV cabin can satisfy the ASHARE proposed value range of ±0.5. The results showed a significant reduction in the temperature fluctuations for cabin thermal comfort and battery thermal management thermal controlling. It offers a satisfactory reference for the refrigerant thermal load distribution strategy applied with the heat pump system connected to the battery and cabin by the dual evaporator.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4288732
    Collections
    • Journal of Electrochemical Energy Conversion and Storage

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV