Show simple item record

dc.contributor.authorNayak, Aniruddh N.
dc.contributor.authorGabriel, Stefan M.
dc.contributor.authorSpenciner, David B.
dc.contributor.authorMason, Courtney E.
dc.contributor.authorJacofsky, Marc C.
dc.date.accessioned2022-05-08T09:44:34Z
dc.date.available2022-05-08T09:44:34Z
dc.date.copyright2/18/2022 12:00:00 AM
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.otherbio_144_07_071006.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285529
dc.description.abstractMultiple biomechanical shoulder simulators have been described in the literature, with a trend toward increasing complexity to better simulate clinical scenarios. Our objective was to develop an advanced, novel shoulder joint simulator and compare outcomes at two separate institutions, for a typical shoulder joint motion simulation. Identical shoulder simulators were developed &amp
dc.description.abstractdeployed at both institutions. Eight cadaveric upper extremities were tested by simulating actively controlled, arm elevation in the plane of the scapula for two sequential test conditions (intact and nondestructive simulated cuff-tear), each repeated for a total of five trials. Muscle forces and joint translations were recorded for both conditions. The intact condition was repeated following simulated cuff-tear to assess effect of testing order. Statistical analyses were aimed at assessing repeatability and reproducibility of results within specimens, between specimens, and between institutions. The highest average forces were observed for the middle deltoid (233N or 32.5% body weight (BW)), followed by infraspinatus (99.0N), and posterior deltoid (93.7N) muscles. Differentiation between test conditions was unhindered by variability between repeated trials. Data from testing repeated over time, and between the two institutions were not significantly different. The novel shoulder simulator produced repeatable results with low trial-to-trial variation and outcomes were comparable between the two institutions. The results demonstrated a consistent response in muscle forces and humeral translation for the simulated rotator cuff tear condition. Such advanced shoulder simulators could thus be used for evaluating and optimizing surgical interventions and implant strategies.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDevelopment and Multisite Assessment of a Novel Shoulder Motion Joint Simulator
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue7
dc.journal.titleJournal of Biomechanical Engineering
dc.identifier.doi10.1115/1.4053362
dc.journal.fristpage71006-1
dc.journal.lastpage71006-8
dc.page8
dc.treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record