• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development and Multisite Assessment of a Novel Shoulder Motion Joint Simulator

    Thumbnail
    View/Open
    bio_144_07_071006.pdf (1.326Mb)
    Date
    2022
    Author
    Nayak, Aniruddh N.
    Gabriel, Stefan M.
    Spenciner, David B.
    Mason, Courtney E.
    Jacofsky, Marc C.
    Metadata
    Show full item record
    Abstract
    Multiple biomechanical shoulder simulators have been described in the literature, with a trend toward increasing complexity to better simulate clinical scenarios. Our objective was to develop an advanced, novel shoulder joint simulator and compare outcomes at two separate institutions, for a typical shoulder joint motion simulation. Identical shoulder simulators were developed &amp
     
    deployed at both institutions. Eight cadaveric upper extremities were tested by simulating actively controlled, arm elevation in the plane of the scapula for two sequential test conditions (intact and nondestructive simulated cuff-tear), each repeated for a total of five trials. Muscle forces and joint translations were recorded for both conditions. The intact condition was repeated following simulated cuff-tear to assess effect of testing order. Statistical analyses were aimed at assessing repeatability and reproducibility of results within specimens, between specimens, and between institutions. The highest average forces were observed for the middle deltoid (233N or 32.5% body weight (BW)), followed by infraspinatus (99.0N), and posterior deltoid (93.7N) muscles. Differentiation between test conditions was unhindered by variability between repeated trials. Data from testing repeated over time, and between the two institutions were not significantly different. The novel shoulder simulator produced repeatable results with low trial-to-trial variation and outcomes were comparable between the two institutions. The results demonstrated a consistent response in muscle forces and humeral translation for the simulated rotator cuff tear condition. Such advanced shoulder simulators could thus be used for evaluating and optimizing surgical interventions and implant strategies.
     
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285529
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV