    Development of a Lifetime Pressure Sensitive Paint Procedure for High-Pressure Vane Testing

    Thumbnail
    View/Open
    turbo_144_5_051005.pdf (1.634Mb)
    Date
    2022
    Author
    Aye-Addo, Papa Aye N.
    Paniagua, Guillermo
    Cuadrado, David G.
    Bhatnagar, Lakshya
    Castillo Sauca, Antonio
    Braun, James
    Gomez, Mateo
    Meyer, Terrence
    Bloxham, Matthew
    Metadata
    Show full item record
    Abstract
    Optical measurements based on fast response pressure sensitive paint (PSP) provide enhanced spatial resolution of the pressure field. This paper presents laser lifetime PSP at 20 kHz, with precise calibrations, and results from a demonstration in an annular vane cascade. The laser lifetime PSP methodology is first evaluated in a linear wind tunnel with a converging-diverging nozzle followed by a wavy surface. This test section is fully optically accessible with maximum modularity. A data reduction procedure is proposed for the PSP calibration, and optimal pixel binning is selected to reduce the uncertainty. In the annular test section, laser lifetime PSP was used to measure the time-averaged static pressure field on a section of the suction surface of a high-pressure turbine vane. Tests were performed at engine representative conditions in the Purdue Big Rig for Annular Stationary Turbine Analysis module at the Purdue Experimental Turbine Aerothermal Lab. The 2D pressure results showed a gradual increase of pressure in the spanwise and flow directions, corroborated with local static pressure taps and computational results. The variation in PSP thickness was measured as a contribution to the uncertainty. The discrete Fourier transform of the unsteady pressure signal showed increased frequency content in wind-on conditions compared to wind-off conditions at the mid-span and 30% span. Compared to the mid-span region, the hub end wall region had an increase in frequencies and pressure amplitude. This result was anticipated given the expected presence of secondary flow structures in the near hub region.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284510
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV