    Finite Element Analysis and Bench Testing of Ventricular Septal Defect Occluder

    Thumbnail
    View/Open
    med_016_03_031002.pdf (4.242Mb)
    Date
    2022
    Author
    Li, Yiming
    Song, Chengli
    Sun, Kun
    Metadata
    Show full item record
    Abstract
    The mechanical behavior of the ventricular septal defect (VSD) occluder is strongly linked to complications following transcatheter closure of the VSD. Methods: A mechanical model of the VSD occluder was constructed by theoretical modeling of the braiding structure. The mechanical properties of the VSD occluders with different braiding angles (30 deg, 45 deg, 60 deg), materials (nitinol (NiTi), polydioxanone (PDO)), and waist-heights (3 mm, 4 mm) were studied by finite element analysis and validated by bench tests. Under 1 mm radial shrinkage, the bending angles at the waist of the 30 deg NiTi, 45 deg NiTi, 60 deg NiTi and 45 deg PDO occluders were 112 deg, 121 deg, 155 deg and 155 deg, respectively. The maximum principal strains at the waist were 16.62%, 8.19%, 1.20%, and 0.66%, respectively. With 0.5 rad axial bending, the maximum radial deformations at the waist were 1.73, 1.44, 0.41 and 1.68 mm, respectively. When the occluders were implanted into VSD with the mean thickness of 3.5 mm, considerable stress developed at the hole's margin and the contact area. The area with the 3 mm occluder was much bigger than that with the 4 mm occluder. Conclusions: the 60 deg NiTi occluder showed better ability to fit the deformation of the defect than the other NiTi occluders, and the 45 deg PDO occluder performed better under compression conditions but poorly under bending conditions than the 45 deg NiTi occluder. The choice of the appropriate waist-height is beneficial to eliminate associative complication by reducing the contact stress.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283982
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV