    Experimental and Numerical Study of an Open Impeller Centrifugal Compressor Stage Utilizing Three-Dimensional (3D) Diffuser End Wall Contouring for Operating Range Extension

    Thumbnail
    View/Open
    turbo_143_9_091018.pdf (1.408Mb)
    Date
    2021
    Author
    Hermann, Daniel
    Wirsum, Manfred
    Robinson, Douglas
    Jenny, Philipp
    Metadata
    Show full item record
    Abstract
    Highly efficient and concurrent flexible operation are heavy demands on today's centrifugal compressor units. Diffuser end wall contouring is a measure to delay the incipience of instability and therefore to extend the compressor's operating range while maintaining efficient performance. In the presented paper, a hub-side wall contouring, applied in the vaneless space upstream the diffuser vane's leading edge and within the diffuser passage of a state-of-the-art centrifugal compressor stage with an open impeller, is examined. Computational fluid dynamics computations are performed for both a baseline diffuser design with parallel channel walls and the hub-side wall contoured diffuser design. Comparisons of characteristic and diffuser stability decisive flow variables are made in perpendicular sections along an extrapolated camber line of the diffuser vane for full span, near shroud and near hub wall. In operating points near the stability limit at two different stage Mach numbers, the stabilizing effect of the hub-side wall contouring on the diffuser flow is clearly shown. In a scale-model test rig, experimental data including pneumatic five-hole probe data for a full diffuser blade-to-blade passage, static wall pressures at various planes as well as total temperatures were measured. The experimental data are utilized for the validation of the presented numerical calculations. The flow stabilizing effect of the hub-wall contouring is clearly visible in the measurements, which showed 8% range extension at highest stage Mach number Mu2 = 1.16 and a range extension of 2% at design stage Mach number Mu2 = 1.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4279014
    Collections
    • Journal of Turbomachinery

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV