    A Vibratory, Subresonant Diagnostic Device to Measure Dental Implant Stability Via Angular Stiffness

    Thumbnail
    View/Open
    med_015_03_031015.pdf (1.343Mb)
    Date
    2021
    Author
    Xu, Weiwei
    Wood, Darwin S.
    Liu, Yifeng
    Shen, I. Y.
    Metadata
    Show full item record
    Abstract
    Stability of a dental implant reflects quality of osseointegration between the implant and its surrounding bone. While many methods have been proposed to characterize implant stability, angular stiffness at the neck of the implant has been proven to be a rigorous and accurate measure. Nevertheless, fast and reliable measurements of the angular stiffness in a clinical environment are not yet available. This article is to demonstrate a novel stability diagnostic device that can measure the angular stiffness accurately in clinical environments. The device consists of a sensing unit, a controller unit, and a mobile app. In the sensing unit, a coupler attaches a buzzer motor and a tiny accelerometer to an abutment of an implant, whose angular stiffness is to be measured. The buzzer vibrates at a frequency below the resonance frequency of the implant–bone–abutment system. Meanwhile, the accelerometer measures the abutment's vibration. The controller unit powers the buzzer, reads the accelerometer data, and transmits the data to the mobile app. The mobile app postprocesses the data and extracts the angular stiffness through use of a finite element model and a nonlinear regression algorithm. The extracted angular stiffness is compared with a calibrated angular stiffness, which is obtained independently via a force hammer and a laser Doppler vibrometer. The comparison shows reasonable agreement, with the difference being in the range of 4–20%.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278737
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV